Fume Extraction - Dometic RM 7401 Mode D'emploi

Masquer les pouces Voir aussi pour RM 7401:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.7

Fume extraction

Fume extraction must be arranged in such a way as to provide complete
extraction of all products of combustion to an area outside the living area.
The flue system must slope in an upward direction in order to avoid a
build-up of condensation.
CAUTION
Fitting the fume flue in the upper ventilation grille
6.7.1
1. Connect T-piece (E) to adaptor (F) or tail pipe (K) as required and affix with
screw (G). Ensure that heat baffle (H) is lodged in the correct position.
2. Insert flue pipe with cover plate (C) through the appropriate aperture in frame (I)
and connect to T-piece (E). If necessary, shorten flue pipe (C) to the required
length.
3. Insert ventilation grille(D) into mounting frame (I) and fasten, using the locking
handle on the left of the grille.
4. Put cap (B) on flue pipe (C).
5. Insert extractor insert (A) into ventilation grille (D).
This type of fume extraction allows use a winter cover.
An installation that is not carried out by qualified persons
causes a reduction in the cooling capacity and will jeopardize
the manufacturer's guarantee.
23
min. 10 mm
max. 20 mm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rm 7551 ulRm 7551

Table des Matières