the heater can turn on at any time.
risks.
3. UNPACKING
WARNING: The packaging material is not
a toy. Keep the plastic bag out of the reach
3.1. Remove all packaging materials used
to wrap and deliver the heater and dispose
them in compliance with current regulations.
3.2. If the heater is placed on a moving
platform, make sure it is moved gently.
3.3. Check for any damage that might have
happened during transport. If the heater
looks damaged, immediately inform the
dealer from which it was purchased.
4. ASSEMBLY
and a chimney depending on the model (PIC.
5-6). These parts, which come with the relative
nuts and bolts, are in the heater's packaging.
5. FUEL
DIESEL or KEROSENE.
use only diesel or kerosene fuel.
Never use petrol, naphtha, paint solvents, alco-
Non-toxic, anti-freeze additives can be used in
case of very low temperatures.
It is advisable to use winter diesel below 5°C.
Airchaud Diffusion - 35 route de Colmar, 67600 Sélestat
SIRET : 444 448 898 00015

6. OPERATING PRINCIPLES

A. Combustion chamber and burner, B. Fan,
C. Motor, D. Pump, E. Tank, F. Chimney
(indirect models).
The pump draws fuel from the tank and brings
it to the operating pressure. The fuel is brought
-
to the nozzle that sprays it into the combustion
chamber. The combustion is carried out with a
-
is pushed outside via the rotation of the fan.
In direct models (PIC. 7) combustion products
(PIC. 8) combustion products are
-
outside through the chimney. A series of
sensors connected to an electronic control
-
board constantly keep the correct operation of
the heater monitored and stops the cycle in the
event of anomalies.
7. OPERATION
heater.
VERIFY THE CONGRUENCE BETWEEN
POWER TENSION SUPPLY, SETTING OF
DUAL VOLTAGE SWITCH AND TYPE OF
PLUG, BECAUSE IMPROPER USE MAY
CAUSE DAMAGE TO THE HEATER.
7.1.1. Please follow the safety instructions.
7.1.2. Check if there is enough fuel in the tank.
7.1.3. Close the tank cup (PIC. 13).
7.1.4. Connect the power supply plug to the
mains electricity (PIC. 14) (SEE VOLTAGE
IN THE "TECHNICAL DATA TABLE").
7.1.5. Set the "I/0" switch to "I" (PIC. 15). The
heater should turn on within a few seconds. If
the heater does not start, refer to paragraph
"12. TROUBLESHOOTING".
7.1.6. For models with a room thermostat,
check the position of the knob (PIC. 16).
Tél. : 03 88 08 67 05
Fax : 03 88 08 67 39
directed
contact@airchaud-diffusion.fr
www.airchaud-diffusion.fr
en
it
de
es
fr
nl
pt
da
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hpv serieHp30Hp50Hp65Hp110Hpv20 ... Afficher tout

Table des Matières