Télécharger Imprimer la page

Accessories - Bürkle 5606-0600 Instructions D'emploi

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Completing filling and dismounting
1. After the last pump stroke, leave the piston rod in
the lower position and insert it into the pump up to
the stop.
2. Close the shut-off valve on the discharge tube.

Accessories

Type
PP barrel screw joint
PP barrel screw joint
PP barrel screw joint
SafetyBox
Drain safety stand
More accessories can be found at www.buerkle.de
Troubleshooting
Problem
Liquid is not pumped.
Specification
R 2", steel fine outer thread
Mauser 2", coarse outer thread
TriSure, coarse outer thread
Incl. safety goggles and protective gloves
Total length 117 cm, Ø 35 mm
To eliminate the error
Bottom valve is polluted. Clean the pump.
If there is only little residual liquid in the container, the pumping must be carried
out for a longer time.
WARNING!
Some liquid will continue to run. Bodily injury due
to escaping liquid.
`
`
Close the shut-off valve on the discharge tube
before dismounting.
3. Carefully unscrew the instrument from the container.
4. Rinse the instrument with a pH-neutral fluid.
English
Number
Item No.
1
5600-3130
1
5600-3170
1
5600-3180
1
2507-9000
1
5618-1000

Publicité

loading

Ce manuel est également adapté pour:

5606-10005606-0400