3. Commissioning, operation
3.2 Tightening torques
EN
Only ever screw in, or unscrew, the instrument via the spanner flats and to the
■
prescribed torque using an appropriate tool.
The correct torque depends on the dimensions of the connection thread and the sealing
■
used (form/material).
When screwing in or unscrewing the instrument, do not use the connection head as
■
contact surface.
When screwing in the instrument, please observe that the threads are not skewed.
■
Assure that the purge gas connection is tighten and no gas can escape, so that there is
■
no carry-through between zones.
8
AI_14302226_TC82_TC83_ATEX_Ex-d_en_de_fr_es.indd 8
AI_14302226_TC82_TC83_ATEX_Ex-d_en_de_fr_es.indd 8
Connection head, selectable (example)
Tightening torques between connection head and neck tube
Thread
1/2 NPT
3/4 NPT
M20 x 1.5 with counter nut
M24 x 1.5 with counter nut
Tightening torques between purge connection and purge piping
Thread
1/4 NPT
1) Turns from finger tight (T.F.F.T)
WIKA additional operating instructions TC82, TC83, flameproof enclosure (Ex d)
Tightening torques in Nm
Connection head material
Aluminium
Stainless steel
T.F.F.T 2 - 3
T.F.F.T 2 - 3
1)
T.F.F.T 2 - 3
T.F.F.T 2 - 3
1)
23
25
27
30
Tightening torques in Nm
Connection head material
Aluminium
Stainless steel
T.F.F.T 2 - 3
1)
T.F.F.T 2 - 3
18.01.2023 07:54:48
18.01.2023 07:54:48
1)
1)