Installation of the external Antenna Kit

1.3 Retrofitting for initial Situation (C)

DANGER!
Lethal danger caused by high voltages in the inverter.
All work on the inverter must be carried out by a qualified electrician.
This section refers solely to initial situation (C). For the different initial situations, please refer to
section "Installation of the external Antenna Kit" on page 20.
Remove existing antenna
1.
Open the inverter as described in the
inverter documentation.
2.
Unscrew the antenna cable from the
antenna connection on the Radio
Piggy-Back in the inverter housing.
3.
Unscrew the threaded sleeve of the PG
screw fitting.
4.
Remove the entire antenna cable from the
inverter housing by pulling the antenna tip.
In the process, the antenna spring is also
removed from the PG screw fitting. The PG
screw fitting itself remains permanently
attached to the inverter housing (see figure
on the following page).
26
BEAMAW-BXX073022
Radio Piggy-Back
PG screw fitting
Antenna tip
Threaded sleeve