Télécharger Imprimer la page

Suntec Wellness KLIMATRONIC IMPULS 3.5 Eco R290 APP Mode D'emploi page 18

Masquer les pouces Voir aussi pour KLIMATRONIC IMPULS 3.5 Eco R290 APP:

Publicité

Functions
1. Switch On and Off
-
Please press the POWER button to turn on the unit.
-
The unit starts in fan mode by default. ("Fan" indicator for fan speed lights up)
-
Please press the MODE button to select the desired function.
-
Please press the POWER button again to turn off the unit.
2. Functions
-
The device has four functions: Cooling, ventilation, heating and dehumidification. For night operation,
we recommend that you operate the unit in sleep mode.
2.1 Cooling Mode
-
Please press the MODE button repeatedly until the "Cool" indicator lights up.
-
Press the up/down button to set the temperature. The temperature can be set between 16℃ and 32℃.
-
Please press the fan speed button repeatedly until the desired indicator lights up.
-
Please press the oscillation button in order to activate or deactivate the automatic vertical movements
of the fins.
NOTE: The air conditioner stops when the room temperature is below the set temperature.
2.2 Fan Mode
-
Please press the MODE key repeatedly until the "Fan" indicator lights up.
-
In ventilation mode, the room air is circulated but not cooled.
-
Please press the SPEED button to select high, medium or low speed.
2.3 Dehumidification Mode
-
Press the MODE button on the control panel or remote control until the "Dry" indicator lights up. The fan
speed cannot be selected. The user should connect the drainage hose to the drain at the bottom of the
unit.
Note: In this mode, the fan speed switches to Low and cannot be set.
2.4 Sleep Mode
The cooling mode can be activated in sleep mode.
In Cooling Mode:
After 1 hour the preset temperature is automatically increased by 1 ℃, after another hour the preset
temperature is automatically increased again by 1 ℃.
In Heating Mode:
After 1 hour the preset temperature is automatically decreased by 1 ℃, after another hour the preset
temperature is automatically decreased again by 1 ℃.
2.5 Heating Mode
-
Please press the MODE button repeatedly until the "Heat" indicator lights up.
-
Press the up/down button to set the temperature. The temperature can be set between 16℃ and 32℃.
-
Please press the fan speed button repeatedly until the desired indicator lights up.
-
Please press the oscillation button in order to activate or deactivate the automatic vertical movements
of the fins.
3. TIMER 1h-24h:
When the unit is switched on, press the TIMER button first. Now you can set the desired switch-off time
with the up/down buttons.
When the unit is switched off, press the TIMER key to set the switch-on time.
Deactivate Timer: Press the Up/Down button repeatedly until '00' appears on the display.
Note: If you press the POWER button during this time, the timer function will be deactivated.
4. Automatic Frost Protection:
At low room temperatures, frost may accumulate on the evaporator during operation. In this case, the
unit automatically starts defrosting and the POWER LED flashes. The defrost control sequence is as
follows:
When the unit is operating in cooling mode or dehumidification mode, the ambient temperature sensor
detects the evaporator coil temperature. As soon as this drops below -1°C, the compressor is switched
off. After the compressor has stopped operating for 10 minutes or reaches the coil temperature 7℃, the
unit restarts in cooling mode.
5. Overload Protection:
In the event of a power failure, there is a 3-minute delay until the compressor restarts to protect the
compressor.

Publicité