Functioning Of Slimstone-2 - Locinox SlimStone-2 Manuel

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
In case an invalid number is entered, all lights
flash three times. Start over. Menu [5] remains
activated.
6.7 SET PULSE REPETITION [7]
EN
If one or both of the relays are set to pulse mode,
additional pulses can be given by pressing [#]
without the need to re-enter the PIN code. This menu
allows setting the duration of this pulse repetition
timeframe.
• Access programming mode (see 6. 1 )
• Press [7] and confirm with [#]
• [7] and [#] are both lit
• Enter the timeframe within which pulse repetion is
allowed (between 1 and 99 seconds), and press
[#] (0s will disable pulse repetition)
• If a valid value is entered all lights will light up, you
will return to the main menu
In case of an invalid value, all lights will flash
three times. Menu 7 remains activated.
By default the value is set to 'no pulse repeti-
tion'.
6.8 KEYPAD HEATING [8]
• Access programming mode (see 6. 1 )
• Press [8] and confirm with [#]
• [8] and [#] are both lit
• Select the mode for the keypad heating:
[1] Full power heating (default): The keypad
heating can consume up to 12W of power
[2] Half power heating: The power consumed for
keypad heating is limited to a maximum of 6W.
[3] No heating: The keypad heating is disabled.
• Press [1], [2] or [3] and confirm with [#]. When
all LEDs flash, your choice has been saved.
• You are back in the main menu of the
programming mode
In case of an invalid value, all lights will flash three
times. Start over. Menu [8] remains activated.
6.9 FACTORY RESET [0]
• Access programming mode (see 6. 1 )
• Press [0] and confirm with [#]
• [0] will flash rapidly to indicate an irreversible
action can be taken
• Enter the Master PIN and confirm with [#] for 2
seconds
• When all LEDs flash, the factory reset is complete.
12
All settings are restored to default values except
for the Master PIN
6.10 FACTORY RESET UPON LOSS
OF MASTER PIN
Perform a factory reset without a Master PIN:
• Switch the power supply off and on, enter the
default Master PIN '12345' and confirm by press
and holding [#] for 2 seconds within 20 seconds
• The factory reset is complete
• In case of a factory reset as described above, the
Master PIN is reset to '12345'
7. FUNCTIONING OF
SLIMSTONE-2
7.1 ENTER A CORRECT CODE
• Enter a personal code (min. 4 - max. 8 digits)
• Press [#] to confirm the code
• In case the code is only valid for 1 relay, the relay
will be activated immediately
• In case the code is valid for both relay 1 and 2,
buttons [1] and [2] will flash. Press [1] and/or [2]
to activate relay 1 and/or relay 2.
• The corresponding button lights up, and a light
sequence runs from the bottom to the top during
the time the relay is energised (default time is 8
seconds)
• If the sequence light stops, the relay is no longer
energised. The SlimStone-2 is ready for a new
code.
7.2 ENTER A WRONG CODE
• Enter a wrong code
• Press [#] to confirm the code
SlimStone-2

Publicité

Table des Matières

Dépannage

loading

Table des Matières