4.
CABLING
The SlimStone-2 is equipped with a 2 m long 10
conductor cable.
See p. 1 18 for a detailed connection scheme.
EN
Power supply
AC1
AC2
Relay
Relay 1 COM
Relay 1 NO
Relay 1 NC
Relay 2 COM
Relay 2 NO
Relay 2 NC
Override button
Override 1
Override 2
Unused cable ends must be insulated separate-
ly to ensure a proper functioning of the keypad.
5.
CONTROL INPUTS
• You can connect an external button or actuator
that will activate the relays and have priority over
PIN code. For example, using an intercom or
free exit.
• To activate the first relay, connect the NO
contact of the external button for relay 1 between
J (override 1) and the 0V line (in case of DC),
or one of the power lines (in case of AC).
• To activate the second relay, connect the NO
contact of the external button for relay 2 between
I (override 2) and the 0V line (in case of DC),
or one of the power lines (in case of AC).
• For more details on control inputs,
see the scheme on page 63
Attention! This must be a dry contact with NO
function.
• The corresponding button lights up, and a light
sequence runs from the bottom to the top while
the relay is energised.
10
Blue
Brown
Black
Orange
Red
Black/Blue
Orange/Blue
Red/Blue
White
White/blue
6.
PROGRAMMING
6.1 ACCESS PROGRAMMING
MODE
• Press [#] for 5 sec, [#] will start flashing
• Enter the Master PIN and press [#] (default
12345). If correct, [#] will remain lit as long as the
programming mode is activated.
• If a wrong Master PIN is entered, the
programming mode ends and the time out
procedure as described in 7.2 applies.
If only [#] is lit, you are in the main menu of the
programming mode.
For safety reasons we strongly recommend to
change the Master PIN upon first use.
• Select a menu number and confirm with [#]. The
following menus are available:
[9] set Master PIN
[1] manage PIN code
[3] set hold time relay 1
[4] set hold time relay 2
[5] set lighting mode
[7] pulse repetition
[0] factory reset
See next paragraph for detailed information
The programming mode ends
automatically when there is no activity
for 60 seconds.
• After selecting a menu, it's possible to return to the
main menu by pressing the [C] key
• Press [C] for 5 seconds to exit the programming
mode
6.2 SET MASTER PIN [9]
• Access programming mode (see 6. 1 )
• Press [9] and confirm with [#]
• [9] and [#] are both lit
The default Master PIN is 12345. It always has
to be a 5-digit code.
• Enter a new 5-digit Master PIN and press [#].
Repeat this step.
• If both codes are equal, all LEDs will light briefly
and you will return to the main menu of the
programming mode
SlimStone-2