1. ID Code of the Product Type
2. ID of the Product
3. Intended Use
4. Manufacturer
5. System of assesment and
verification of constancy of performance
6. Notified Body
7. Harmonised technical specifications
8. Declared Performances
Classification according to EN179:2008
Performance characteristics
Ability to release
(for locked doors on escape routes)
Release function
Release operation
Lever handle design
Exposed edges and corners
Lever handle installation
Operating element projection
Lever handle free end
Lever handle operating gap
Test rod
Accessible gap
Door free movement
Keepers
Door mass and door dimensions
Release force
Security requirement
Durability of ability to release
(for locked doors on escape routes)
Corrosion resistance
Temperature range
Lubrication
Re-engagement force
Durability
Abuse resistance - operating element
Final examination
Selfclosing ability C
(for fire/smoke doors on escape routes)
Durability of selfclosing ability C against
aging and degradation
(for fire/smoke doors on escape routes)
Resistance to fire E (integrity) and
I( insulation)
Control of dangerous substances
9. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8
The declaration of performance is issued under the sole responsibility of LOCINOX
Waregem, 15/03/2021
PAGE 7

DECLARATION OF PERFORMANCE

DOP Nr: DOP001 EN179 LP-A2-SA
LPKQ - Panic Lock
LPKQ40*A2 + SA keep
LPKQ60*A2 + SA keep
Panic lock on single exit door
LOCINOX
Mannebeekstraat 21
B-8790 Waregem
System 1
SKG-IKOB
Poppenbouwing 56
4191 NZ Geldermalsen
EN179:2008
3 7 6 0 1 4 2 2 A B
Performance
< 1 s
following the direction of the door opening
movement of lever handle in a downward rotational direction
> 0,5 mm
X>=120 mm; Z <=150mm
Grade 2 - W<100mm
U>=40 mm, a <=30°
test block can be passed freely between lever handle
and surface of the door
Test rod dia 10 mm does not fit in gaps
Test block placed in any accessible gap in any orientation does
not prevent correct operation of the emergency exit device
Once the door has been released to open, the bolt head does
not restrict the free movement of the door
The keeper protects the door frame from damage which may
be caused by the door closing and opening
Mass<= 200kg, height <= 2520 mm, width <=1320 mm
<=70N
Grade 2; the device remains in the locked position when a force of
1000 N is applied to the door
Grade 4; very high resistance (240 h)
Operating forces compliant between -10°C and +60°C
not needed
<=50N
Grade 7; 200.000 test cycles
N/A
At the end of the program the emergency exit device is still
operable and meets the requirements of 4.2.2 and 4.1.21
N/A
N/A
N/A
The materials in this product do not contain or release any
dangerous substances in excess of the max. levels specified in
existing European material standards or any national regulations
Dominique Debaveye, Quality Manager
Harmonised technical
specifications
4.1.2 of EN179:2008
4.1.3 of EN179:2008
4.1.4 of EN179:2008
4.1.8 of EN179:2008
4.1.12 of EN179:2008
4.1.13 of EN179:2008
4.1.15 of EN179:2008
4.1.16 of EN179:2008
4.1.18 of EN179:2008
4.1.20 of EN179:2008
4.1.21 of EN179:2008
4.1.24 of EN179:2008
4.1.27 of EN179:2008
4.2.2 of EN179:2008
4.2.7 of EN179:2008
4.2.9 of EN179:2008
4.1.9 of EN179:2008
4.1.26 of EN179:2008
4.2.3 of EN179:2008
4.2.4 of EN179:2008
4.2.6 of EN179:2008
4.2.8 of EN179:2008
4.2.3 of EN179:2008
4.2.3 and 4.2.4 of EN179:2008
4.1.10 and annex B of EN179:2008
4.1.29 of EN179:2008
2021-10-05 - rev 7