Electrical Connection - Cooper Lighting Solutions Portfolio LuxWire Directives D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions – Portfolio LuxWire™ Cylinders
3.
Rotate side clips (3) into place to securely attach trim
assembly to LED engine. (Figure 7)
Figure 7.
4.
Plug in the luminaire quick disconnect on the module.
(Figure 8)
Figure 8.
5.
Find the green tether inside cylinder and attach it to the
heatsink using the screw and lock washer located in
the envelope attached to the tether. (Figure 9)
Figure 9.
Green
Ground
Wire
4
Cooper Lighting Solutions
Screw
Lockwasher
Heatsink Screw
Boss
IB520143ML
Installation instructions
6.
Install the LED Engine and trim assembly by inserting
the torsion springs into the spring receivers located
inside the housing. (Figure 10)
Figure 10.
Cleaning
1.
To Clean Trims:
2.
Gently wipe with soft, clean, dry lint-free cloth to
remove dust.
3.
Wipe with mild detergent solution on a soft, clean cloth
to remove fingerprints and stains.
4.
Rinse with clean water and dry with soft, clean, dry lint-
free cloth.

Electrical Connection

Make certain no bare wires are exposed outside of wire nut
connectors.
1.
Provide electrical service according to the "National
Electrical Code" or your local electrical code to the
cylinder housing assembly. Supply wire insulation must
be rated for at least 90°C.
2.
Connect supply lead wires to cylinder housing lead
wires (line, neutral and ground) in the fixture using
properly sized wire nuts. Be careful not to leave any
bare conductors outside of the wire nut connectors.
3.
Connect white to white, black to black, and green (from
electrical service) on the supply side to the green wire
in the cylinder housing assembly.
Torsion Spring