Instrucciones de instalación – Prevail / USSL
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this
product must be performed by a qualified electrician. This product must be installed in accordance
with the applicable installation code by a person familiar with the construction and operation of the
product and hazards involved.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting
any maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Refer to product label for specific minimum supply conductor requirements.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind
that may arise from the improper, careless, or negligent installation, handling or use of this product.
NOTICE: Green ground wire provided in proper location. Do not relocate.
ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on
delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
Safety: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area
of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to
installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation
and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and
maintained according to the following recommendations.
Regulatory Information: This equipment has been test and found to comply with the limits of a Class A digital
device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
WARNING
WARNING
Brand Logo
reversed out of
black
INS #
INS #

Publicité

Table des Matières
loading

Sommaire des Matières pour Cooper Lighting Solutions Prevail

  • Page 1 Failure to comply with these instructions may result in death, serious bodily injury and property damage. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
  • Page 2: Tools Required

    Installation Instructions – Prevail / USSL INSTALLATION Split Washer This lighting fixture has been shipped complete with one of several mounting options. Please follow the installation Washer instructions specific to the catalog part that you ordered. ote: Care must be taken not to set lighting fixture down on optical lenses or lift the fixture by the lens.
  • Page 3 Installation Instructions – Prevail / USSL Tools required .44 dia #2 Phillips head screw driver, torque wrench. Wall Plate [11.20] ote: Hardware and tools to mount wall plate to wall not supplied. 7 .12 8.00 Wall Mount (Figure 6.) [180.85] [203.20]...
  • Page 4 Installation Instructions – Prevail / USSL Tools required #2 Phillips head screw driver and pliers. Optic Plastic Front of Pins Fixture House Side Shield (Figure 9. and Figure 10.) Remove plastic push pins on back side of optic. Pole (Figure 9.)
  • Page 5 La désobéissance aux instructions suivantes représente un risque de blessures graves ou mortelles et de dommages matériels. EXONÉRATION DE RESPONSABILITÉ : Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou d’une utilisation inappropriée, imprudente ou négligente de ce produit.
  • Page 6: Herramientas Necesarias

    Instructions d’installation – Prevail  / USSL INSTALACIÓN Rondelle fendue Rondelle fendue Esta luminaria se ha enviado completa con una de las varias opciones de montaje. Siga las instrucciones de instalación Rondelle Rondelle específicas para la pieza que haya solicitado del catálogo.
  • Page 7 Instructions d’installation – Prevail  / USSL Instale la cubierta del brazo y ajuste los tornillos Philips Conecte los cables en el interior de la luminaria. con un torque de 20 pulg.-lb. (2,3 Nm). Consulte el diagrama de cableado para conocer las conexiones de la alimentación.
  • Page 8: Outillage Nécessaire

    Instructions d’installation – Prevail  / USSL • Le fil de mise en terre provenant de l’alimentation avec Resserrez les vis. le fil vert du luminaire. Insérez l'interrupteur photoélectrique (ou fiche de mise • Le fil neutre provenant de l’alimentation avec le fil blanc en court-circuit) dans le réceptacle et tournez-le pour le...
  • Page 9: Renuncia De Responsabilidad

    El incumplimiento de estas instrucciones puede provocar la muerte, lesiones corporales graves y daños materiales. RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o pérdidas de ningún tipo que puedan derivarse de la instalación, manipulación o uso incorrecto, descuidado o negligente de este producto.
  • Page 10 Instrucciones de instalación – Prevail / USSL INSTALACIÓN Arandela ranurada Esta luminaria se ha enviado completa con una de las varias opciones de montaje. Siga las instrucciones de instalación Arandela específicas para la pieza que haya solicitado del catálogo. ota: Se deben tomar precauciones para no bajar la Perno de 1/2”...
  • Page 11 Instrucciones de instalación – Prevail / USSL Instale la cubierta del brazo y ajuste los tornillos Philips Conecte los cables en el interior de la luminaria. con un torque de 20 pulg.-lb. (2,3 Nm). Consulte el diagrama de cableado para conocer las conexiones de la alimentación.
  • Page 12 Instrucciones de instalación – Prevail / USSL • Cable de conexión a tierra del lado de la aliment ación con el terminal verde de la luminaria. Óptica Tachuelas • Cable neutro del lado de la alimentación con el terminal blanco de la luminaria.
  • Page 13 Siga las instrucciones recomendadas por el proveedor del fotocontrol respecto de su proximidad Tornillos Pantalla a las fuentes de iluminación. La posición final del lateral del tipo Torx fotocontrol puede verse afectada por señalizaciones alojamiento iluminadas, reflexiones en las superficies del edificio, reflectores, ramas de árboles, etc.
  • Page 14: Garanties Et Limitation De Responsabilité

    Garanties et limitation de responsabilité Veuillez consulter le site www.cooperlighting.com pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com para conocer nuestros términos y condiciones. Cooper Lighting Solutions is a registered trademark. All trademarks are property of their respective owners.

Ce manuel est également adapté pour:

Ussl

Table des Matières