OPERATION
The hood is operated using the (5) push buttons located on the front edge of the
hood.
The Light Off switch turns the lights off.
The Light On switch turns the lights on.
The Blower Off/Speed switch turns the blower off and changes blower speed to four
different speed settings: high, medium-high, medium-low and low speed. Depress
and hold the button for 2 seconds to turn the blower off.
The Blower On/Speed switch turns the blower on to four different speed settings:
Low, medium-low, medium-high and high speed.
The LED Display:
• Indicates blower speed selection from 1 (lowspeed) to 4 (high speed).
• Flashes the blower speed when the 10-minute delay off has been activated.
• After 30 hours of operation, the center segment of the display blinks and remains lit,
indicating that the filter needs to be cleaned.
The Delay off feature: When pushed, the blower will continue to operate at the
current speed setting for 10 minutes before automatically turning itself off.
The Filter Alarm Reset switch is used to reset the 30-hour filter timer. After the filter
is cleaned or replaced, press this switch once to reset the filter clean alarm.
Light OFF
Light ON
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that
will turn on or speed up the blower if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF.
When this occurs, it is impossible to turn the blower OFF with its switch. If you must
stop the blower, do it from the main electrical panel.
HALOGEN BULBS
This range hood requires two halogen
bulbs (Type T3, 12Volt, 20Watt Max, G-4
Base).
WARNING: Always switch off the
electricity supply before carrying out any
operations on the appliance.
1. Open the cover by prying from the
proper slots. See Fig. 12.
2. Remove the bulb by pulling sideways.
(DO NOT ROTATE)
!
CAUTION: Bulb may be hot.
3. Replace with Type T3, 12Volt, 20Watt
Max, G-4 Base halogen bulb. Do not
touch replacement bulb with bare
hands!
Blower Off/Speed
Blower On/Speed
- 8 -
LED Display
Delay off/
Filter Alarm Reset
Fig.12