Mode
Explanation
In Standby mode, the charger is not charging or providing any power to the battery. Energy Save is activated during this mode, drawing microscopic
power from the electrical outlet. Canbus is enabled in Standby mode. When in Standby, the orange Standby LED will illuminate.
Standby
No Power
For charging 12-volt Wet Cell, Gel Cell, Enhanced Flooded, Maintenance-Free and Calcium batteries. When selected, the 12V white LED will illuminate.
14.5V | 10A | Up To 230AH Batteries
For charging 12-volt AGM batteries. When selected, the 12V AGM white LED will illuminate.
14.8V | 10A | Up To 230AH Batteries
For charging 12-volt lithium-ion batteries, including lithium iron phosphate. When selected, the 12V Lithium blue LED will illuminate. For use on
batteries with Battery Management Systems (BMS) only.
14.6V | 10A | Up To 230AH Batteries
An advanced battery recovery mode for repairing and restoring, old, idle, damaged, stratified or sulfated batteries. When selected, a red LED will
illuminate and flash.
Press & Hold
(3 Seconds)
16.5V | 1.5A | Any Capacity
Force Mode
For charging batteries with a voltage lower than 1V. Press and Hold for five (5) seconds to enter Force Mode. The selected charge mode will then
operate under Force Mode for five (5) minutes before returning to standard charging in the selected mode.
Press & Hold
(5 Seconds)
10A | Up To 230AH Batteries
Using 12V Lithium.
12V Lithium charge mode is designed for 12-volt lithium-ion batteries only, including lithium iron phosphate.
CAUTION. USE THIS MODE WITH EXTREME CARE. THIS MODE SHOULD ONLY BE USED WITH 12-VOLT LITHIUM BATTERIES THAT HAVE A BUILT-IN BATTERY MANAGEMENT
SYSTEM (BMS). LITHIUM-ION BATTERIES ARE MADE AND CONSTRUCTED IN DIFFERENT WAYS AND SOME MAY OR MAY NOT CONTAIN A BATTERY MANAGEMENT SYSTEM
(BMS). CONSULT THE LITHIUM BATTERY MANUFACTURER BEFORE CHARGING AND ASK FOR RECOMMENDED CHARGING RATES AND VOLTAGES. SOME LITHIUM-ION BATTERIES
MAY BE UNSTABLE AND UNSUITABLE FOR CHARGING.
Using 12V Repair. [From Standby Press and Hold 3 Seconds With Clamps Connected to the Battery]
12V Repair is an advanced battery recovery mode for repairing and storing, old, idle, damaged, stratified or sulfated batteries. Not all batteries can be recovered. Batteries tend to become damaged
if kept at a low charge and/or never given the opportunity to receive a full charge. The most common battery problems are battery sulfation and stratification. Both battery sulfation and stratification
(Peak Voltage Measured At 25°C, Amperage Rating Is Bulk Amperage When Above 0°C)
[From Standby Press and Hold 3 Seconds while connected to battery]
[From Standby Press and Hold 5 Seconds while connected to battery, then toggle through modes]