ST 1503 Manuel D'installation page 32

Multi connect system (interface /power take off(pto)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Adapt the adjuster (40) so that, with the lever (41) in disen-
gagement position «B», the pin (43) remains at least 1 mm
from the end of the loophole (44) and the spring (45) cable
(42) is slightly tensioned.
WARNING! - Check that the micro-switch is
working properly along with its interaction with the
machine safety devices.
● Apply the attachment to the interface, check that it
rises and lowers correctly and that the lock system
works properly in a raised position; also check the
correct motion engagement and transmission.
When the attachment is installed, check the spring meas-
urement (45) that must never be lower than 39 mm or higher
than 41 mm, measured on the total coils with the engage-
ment lever (41) in position «A»; if this is not the case, adapt
the adjuster (40) as required.
44
43
1 mm
41
39-41
mm
40 42 45