WARNING
Fire and shock hazard. Damaged heating cable can cause electrical shock, arcing, and fire. Do not
attempt to repair or energize damaged heating cable. Remove it at once and replace with a new length.
PRODUCT SPECIFICATIONS
Cable
Cable
Length
(230 V)
(meter)
FFSLE2-2M
FFSLE2-4M
FFSLE2-8M
FFSLE2-16M
General Specifications for all FFSL Products
Nominal cable width (mm)
Nominal cable thickness (mm)
Heating cable bus wire gauge (AWG)
Cold lead length (m)
Voltage rating (230 V)
Plug rating (Amps)
Circuit breaker sizing minimum (Amps)
Max. exposure temperature
Electrical classification
Exposure to chemicals
Watts/meter at 10 °C
Watts/meter at 0 °C in ice and snow
Outer Jacket Type
All manuals and user guides at all-guides.com
Min. power output at
10°C
on pipe (Watts)
2
34
4
68
8
136
16
272
© BriskHeat® Corporation. All rights reserved.
Nominal power output
at 0°C
in ice and snow (Watts)
68
136
272
544
Nonhazardous areas only
Moisture and flame resistant
thermoplastic elastomer
11
SpeedTrace Self-Regulating
Heating Cable
10.6
5.6
16
2
208-277
15
15
65 °C
None
17
34