IMPORTANT SAFETY INSTRUCTIONS

DANGER
A person who has not read and
understood all operating
Instructions is not qualified to
operate this product.
DANGER
Do not immerse power connection kit or heating
cable in liquid.
Keep volatile or combustible material away from
power connection when in use.
Use power connection kit and heating cable in
approved locations only.
Keep sharp metal objects away from power
connection and heating cable.
Failure to observe these warnings may result in electric
shock, risk of fire, and personal injury.
WARNING
End-User Must Comply to the Following:
Only qualified personnel are allowed to connect
electrical wiring.
Disconnect all supply power at the source before
making any power connections.
All electrical wiring must follow local electrical
codes and highly recommend following NEC
Article 427.
The person who performs the final installation /
wiring must be qualified for this work.
The end-user is responsible for providing a
suitable disconnecting device.
The end-user is responsible for providing suitable
electrical protection device. It is highly
recommended that a ground fault circuit breaker
be used.
Failure to observe these warnings may result in personal
injury or damage to the product and/or property.
®
© BriskHeat
Corporation. All rights reserved.
SLCBLUC Power Connection Kit

Agency Approvals

Approvals valid only when installed in accordance with
all applicable instructions, codes, and regulations.
CAUTION
Inspect all components before use.
Do not use power connection kit or heating cable
if any component is damaged.
Do not repair any damaged or faulty components.
Do not crush or apply severe physical stress on
any component of the system.
Must be mounted away from vibration, impacts,
water and corrosive gases.
Do not operate above rated temperature value.
Fasten power connection kit and heating cable
using approved methods only.
Failure to observe these warnings may result in personal
injury or damage to the product and/or property.
3

PRODUCT OVERVIEW

Description
The SLCBLUC power connection kit is suitable for use only with the SLCBL series heating cables. Includes materials for
one power connection and one end seal connection. Do not use this kit with aluminum feed wires.
Applicaions
Use the SLCBLUC kit with the following heating cables: SLCBL-B, SLCBL-BP and SLCBL-BF. SLCBL-B cable is
designed for pipe freeze protection in dry locations. SLCBL-BP cable is designed for both wet and dry locations, as well as
for roof and gutter de-icing. SLCBL-BF cable is designed for both wet and dry locations, as well as for strong chemical
environments. The cable type is printed on the outer jacket of the cable.
Kit Contents
Item
Qty
Description
Labels
A
4
(2) Heat-trace warning labels
(2) De-Icing snowmelt caution labels
B
1
Standoff pipe mounting bracket
C
1
Lock nut
D
1
Grommet
1/2" NPT Seal fitting with Strain Relief and
E
1
grommet (D)
F
3
Wire nuts
Black heat-shrinkable tube,
G
1
1/2" x 1" (1.3cm x 2.5cm)
Green/yellow heat-shrinkable tube,
H
1
1/4" x 6" (0.25 cm x 0.64cm)
Black heat-shrinkable tubes,
I
2
1/8" x 5-1/2" (0.3cm x 14.0cm)
J
1
Sealing gasket
K
1
End seal kit
Note: Additional Accessories May Be Required.
WARNING:
These components are electrical devices. They must
be installed correctly to ensure proper operation and
to prevent shock or fire. Carefully follow all of the
installation instructions and read these important
warnings.
To minimize the danger of fire from sustained
electrical arcing if the heating cable is damaged or
improperly installed, and to comply with the
requirements of national electrical codes,
ground-fault equipment protection must be used on
each heating cable branch circuit. Arcing may not be
stopped by conventional circuit protection.
Component approvals and performance are based
on the use of specified parts only. Do not substitute
parts and do not use vinyl electrical tape.
The black heating-cable core is conductive and can
short. It must be properly insulated and kept dry.
The conductive layer of this heating device must be
connected to a suitable grounding terminal.
The installer should apply the name place label to
the surface of the junction box.
Keep kit components and heating cable dry before
and during installation.
®
© BriskHeat
Corporation. All rights reserved.
SLCBLUC Power Connection Kit
Additional Materials Required
UL Listed junction box suitable for the location with a
clearance hole for 1/2-inch conduit or 1/2-inch NPT
threaded hub. The minimum size of the junction box is
4.7 x 4.7 x 3.5" (12 x 12 x 9cm).
For heating cable with no outer-jacket, you must use a
metallic junction box to ensure proper grounding.
Your application may require additional accessories for
roof and gutter de-icing applications.
Tools Required
Needle nose pliers, Diagonal cutters, Adjustable wrench,
Pen, Utility knife, Screwdriver, Propane torch or heat gun.
K
Keep components and heating cable ends dry before
and during installation.
Damaged bus wires can overheat or short. Do not
break braid or bus wire strands when scoring the
jacket or core.
Bus wires will short if they contact each other. Keep
bus wires separated.
Heat-damaged components can short. Use a heat
gun or torch with a low-heat flame and move flame
often to avoid overheating, blistering, or charring the
heat shrinkable tubes. Avoid over-heating other
components. Replace any damaged components.
Use only fire-resistant insulation materials such as a
fiberglass wrap. Leave these installation instructions
with the user for future reference.
The cable should not be twisted during installation.
De-energize all power circuits before installation or
servicing. The heating cable should not be
embedded.
CAUTION: Charring or burning the heat-shrinkable tubes in
this kit will produce fumes that may cause eye, skin, nose,
and throat irritation.