Page 1
• To READ ALL warnings, care, and maintenance information. • To purchase the correct water supply hook-up. Para instalación fácil de su llave Delta usted necesitará: • LEER TODAS las instrucciones completamente antes de empezar. • LEER TODOS los avisos, cuidados, e información de mantenimiento.
® Esta es la garantía exclusiva por escrito de Delta Faucet Company y la garantía no es transferible. Delta Faucet Company no será responsable por cualquier daño a la llave de agua que resulte del mal uso, abuso, negligencia o mala instalación o mantenimiento o reparación incorrecta, incluy- Si usted tiene alguna pregunta o inquietud acerca de nuestra garantía, por favor, vea nuestra...
Maintenance If faucet exhibits very low flow: If leak persists–SHUT OFF WATER SUPPLIES. * WARNING: Failure to securely tighten A. Remove and clean Aerator (1) with supplied Replace valve cartridge (3). When reinstalling bonnet nut with a wrench could result wrench (2), or parts, make sure bonnet nut (5) is tightened in water damage.
Page 4
1/2" (12.70mm) IPS Supply Line Connections Position faucet (1) and gasket (2) on sink. Option: If sink is uneven, Note: Be careful when bending the copper tubing. Kinked tubes will use silicone under the gasket. void the warranty. Choose hook-ups for 1/2” I.P.S. connections: (1) Ball nose riser (3/8”...
Page 5
Step 3b Metal Pop-Up Step 3c Remove pivot nut (1). Install horizontal rod Remove stopper (1) and flange (2). Apply silicone to underside of flange (1). Insert (2) and stopper (3) as removable (4) or body (2) into sink. Screw flange (1) into body (2). non-removable (5).
Page 6
Remove aerator (1) using supplied wrench (2) and move faucet handle (3) to the full on mixed position. Turn on hot and cold water supplies (4) and flush water lines for one minute. Important: This flushes away any debris that could cause damage to internal parts. Reinstall aerator. Check all connections at arrows for leaks.
Page 7
Setting The Handle Limit Stop (Optional) This faucet includes an integrated handle limit stop that has two positions. Position because it limits the amount of hot water in the mix; however, this handle limit stop 1, to the left, allows full handle motion (the full range between “all cold” to “all hot”). will not always prevent scalding because it does not compensate for incoming The faucet is set in position 1 in the factory.
Page 8
RP5648 Stopper Tapón Bonde RP52833 Handle & Set Screw RP12516 Manija y Tornillo de Ajuste Strap & Screw Manette et Vis de Calage Barra Chata y Tornillo RP47666 Feuillard et Vis Set Screw RP23060 Tornillo de Ajuste Flange Vis de Calage Reborde Collerette RP51502...