1. Remove present shower head and shower arm with flange.
1. Quite la cabeza y el brazo de la regadera con la brida.
1. Retirez la pomme de douche, le tuyau de la pomme de douche et la collerette.
2. Apply plumber tape to threaded ends of 1/2" (13 mm) iron pipe nipple (not supplied) and thread
into shower riser elbow so that nipple extends past the finished wall no more than 1/2" (13 mm)
and no less than 1/4" (6 mm). Place the supplied installation gasket behind the elbow. Thread
the supplied installation tool onto the base of the elbow; then, using it for additional leverage
(fits a 1/4 inch Allen wrench) screw the supply elbow onto the nipple making sure that the
supply elbow outlet is in a downward facing position. Unthread install tool when finished.
Minimum diameter for hole is 1" (25 mm) with a maximum of 1 1/2" (38 mm).
2. Aplique cinta plomero a las puntas roscadas de la entrerrosca de tubo de hierro de 1/2" (13 mm)
(no proporcionado) y enrósquelo en el codo del tubo vertical de suministro de manera que la
entrerrosca no atraviese la pared acabada más de 1/2" (13 mm) y no menos de 1/4" (6 mm).
Coloque el empaque, para la instalación, que se incluye detrás del codo. Enrosque la herramienta
para la instalación que se incluye en la base del codo; luego, usándola para obtener apalancamiento
adicional (puede usar una llave Allen de 1/4 pulgada) atornille el codo de suministro en la entrer
rosca asegurándose que la salida del codo esté colocada de frente hacia abajo. Cuando termine,
destornille la herramienta de instalación. El diámetro mínimo para el agujero es 1" (25 mm) y un
máximo de 1 1/2" (38 mm).
2. Appliquez du ruban de plomberie sur les filetages du manchon fileté en fer de 1/2 po (13 mm) (non
fourni) et vissez le manchon dans le coude du tuyau vertical d'alimentation de la douche de sorte
qu'il présente une saillie d'au plus 1/2 po (13 mm) et d'au moins 1/4 po (6 mm) par rapport à la
paroi finie. Placez le joint fourni pour l'installation derrière le coude. Vissez l'outil d'installation
fourni sur la base du coude; puis, en l'utilisant pour accroître l'effet de levier (il s'adapte à une vis
Allen 1/4 po), vissez le coude d'alimentation sur le mamelon. La sortie du coude doit être orientée
vers le bas. Dévissez l'outil d'installation après avoir terminé. L'orifice doit avoir un diamètre d'un
moins 1 po (25 mm) et d'au plus 1 1/2 po (38 mm).
3. Attach the shower hose to the threaded supply outlet and proceed with the installation of the hand
shower, following the manufacturers instructions.
CAUTION: To avoid damage to the supply elbow or hose finish during installation, wrap with a
cloth or tape and use only a smooth-jawed wrench. DO NOT OVERTIGHTEN CONNECTIONS.
3. Fije la manguera de la regadera a la toma de agua enroscada y continúe con la instalación de la
regadera de mano, siguiendo las instrucciones del fabricante.
ADVERTENCIA: Para prevenir daño al codo de abastecimiento o al acabado de la manguera
durante la instalación, envuelva con un trapo o cinta y use solamente una llave de tuercas de
mordaza lisa. NO APRIETE DEMASIADO LAS CONEXIONES.
3. Fixez le tuyau souple de la douche au raccord d'alimentation fileté et installez la douche à main
conformément aux instructions du fabricant.
ATTENTION – Pour éviter d'abîmer le fini du coude d'alimentation ou du tuyau souple pendant
l'installation, enrobez-les d'un chiffon ou de ruban adhésif ou utilisez une clé aux mors
lisses. PRENEZ GARDE DE TROP SERRER LES RACCORDS.
50560 SERIES–SUPPLY ELBOW
INSTALLATION INSTRUCTIONS
INSTRUCCIONES PARA EL CODO
ABASTECEDOR–SERIES 50560
SÉRIES 50560–INSTRUCTIONS
D'INSTALLATION DU COUDE
D'ALIMENTATION
1
01/03/2023 Rev. E

Publicité

loading

Sommaire des Matières pour Delta 50560 Serie

  • Page 1 50560 SERIES–SUPPLY ELBOW 43934 INSTALLATION INSTRUCTIONS INSTRUCCIONES PARA EL CODO ABASTECEDOR–SERIES 50560 SÉRIES 50560–INSTRUCTIONS D’INSTALLATION DU COUDE D’ALIMENTATION 1. Remove present shower head and shower arm with flange. 1. Quite la cabeza y el brazo de la regadera con la brida. 1.
  • Page 2 What You Must Do To Obtain Warranty Service or Replacement Parts: A warranty claim may be made and replacement parts may be obtained by calling 1 800 345 DELTA (3358) or by contacting us by mail or online as follows (please include your model number and date of original purchase): ©...
  • Page 3 Pour obtenir la référence des pièces de rechange ainsi que pour avoir accès à d’autres documents techniques et renseignements sur le produit, allez à www.deltafaucet.com 1-800-345-DELTA (3358) www.deltafaucet.com/service-parts Read all instructions prior to installation. CAUTION Failure to read these instructions prior to installation may result in personal injury, property damage, or product failure.
  • Page 4 Copper Tubing Tubería de Cobre Cuivre Iron Pipe Hierro DIVERTER Connect valve body to water supplies using the proper fittings for your valve body type (copper tubing, iron pipe or Distance (1) from the stringer (2) SHUT OFF WATER SUPPLIES. Pex).
  • Page 5 8" - 18" (203 mm-457 mm) 8 po - 18 po Connect top outlet (1) to shower pipe with proper fittings. Connect PRESSURE TESTING & FLUSHING THE INSTALLATION bottom outlet (2) to tub spout pipe with proper fittings. Pipe (3) between Prior to testing, remove cover (1), bonnet (2) and cap (3).
  • Page 6 What You Must Do To Obtain Warranty Service or Replacement Parts: A warranty claim may be made and replacement parts may be obtained by calling 1 800 345 DELTA (3358) or by contacting us by mail or online as follows (please include your model number and date of original purchase): ©...
  • Page 7 Pour obtenir la référence des pièces de rechange ainsi que pour avoir accès à d’autres documents techniques et renseignements sur le produit, allez à www.deltafaucet.com www.deltafaucet.com 1-800-345-DELTA (3358) customerservice@deltafaucet.com Read all instructions prior to installation. CAUTION Failure to read these instructions prior to installation may result in personal injury, property damage, or product failure.
  • Page 8 2 3/4 +/- 1/4 " " (70 mm) Front surface Finished Wall of stringer Pared Acabada Mur de finition Superficie delantera de la ayuda Surface avant d’appui DIVERTER INSTALLATION Consider the plumbing configuration and type and thickness of your Shut off water supplies! Install the diverter so that the word “UP” (1) is facing upward as finished wall before placing your stringer back plate (2).
  • Page 9 Water Flow For 3 Function Diverter / Flujo de agua para Desviadores de 3 posiciones / Écoulement de l’eau pour les inverseurs à 3 positions 1st Position 2nd Position 3rd Position Outlet 1 Outlet 1 Salida 1 Salida 1 1 ª posición 2 ª...
  • Page 10 What You Must Do To Obtain Warranty Service or Replacement Parts: A warranty claim may be made and replacement parts may be obtained by calling 1 800 345 DELTA (3358) or by contacting us by mail or online as follows (please include your model number and date of original purchase): ©...
  • Page 11 Para acceder a documentos técnicos adicionales e información sobre el producto, visítenos en www.deltafaucet. 1-800-345-DELTA (3358) com/p/Your-Model-Number-Here (ejemplo: www.deltafaucet.com/p/9159T-DST) customerservice@deltafaucet.com Pour avoir accès à des documents techniques supplémentaires et à de l’information sur le produit, visitez www.delta- faucet.com/p/Votre-numéro-de-modèle-ci (exemple : www.deltafaucet.com/p/9159T-DST) 02/21/2023 86512 Rev. G...
  • Page 12 Slide Bar Barra deslizable Coulisse Select wall position for wall bar or wall mount bracket based on family’s needs. NOTE: Locate so there will be slack in the hose when hand shower is in extreme up or down position. Follow the mounting instructions for your specific model. Elija la posición en la pared para la barra de pared basada en las necesidades de su familia.
  • Page 13 Slide Bar Barra deslizable Coulisse 51140, 51552, 51567, 57051 & 57530 59210 Series/Series/Seria Series/Series/Seria SLIDE BAR INSTALLATION SLIDE BAR INSTALLATION Model 51140, 51552, 51567, 57051 & 57530: Slide the slide mechanism (1) and elbow Model 59210 - Slide the slide mechanism (1) onto the bar. The slide (10) onto the wall bar (2).
  • Page 14 Wall Mount Shower Mount Montaje en la pared Regadera en la pared Porte-douche Supports Muraux 55011, 55013, 55020, 55021, 55085 54613 & 56613 & 57923 Series/Series/Seria Series/Series/Seria 55552, 55567, 55051, 55140 & 55530 Series/Series/Seria WALL MOUNT BRACKET INSTALLATION Models 55011, 55013, 55020, 55021, 55051, 55085, 55140, 55530, SHOWER MOUNT INSTALLATION Ensure gasket (1) is inserted into the hose 55552, 55567 &...
  • Page 15 86512 Rev. G...
  • Page 16 What You Must Do To Obtain Warranty Service or Replacement Parts: A warranty claim may be made and replacement parts may be obtained by calling 1 800 345 DELTA (3358) or by contacting us by mail or online as follows (please include your model number and date of original purchase): ©...
  • Page 17 Para acceder a documentos técnicos adicionales e información sobre el producto, visítenos en www.deltafaucet. 1-800-345-DELTA (3358) com/p/Your-Model-Number-Here (ejemplo: www.deltafaucet.com/p/9159T-DST) customerservice@deltafaucet.com Pour avoir accès à des documents techniques supplémentaires et à de l’information sur le produit, visitez www.delta- faucet.com/p/Votre-numéro-de-modèle-ci (exemple : www.deltafaucet.com/p/9159T-DST) www.deltafaucet.com 12/13/2022 103739 Rev.
  • Page 18 When the diverter is ready for trim remove plasterguard (1), bonnet Place escutcheon (1) over diverter. Thread trim sleeve (3) onto (2) and test cap (3) from the body. threaded sleeve (2) until escutcheon and backplate are secure against wall. Do not overtighten. Install cartridge assembly (1) into body (2) assuring that the locating Place handle (4) onto stem (5) and tighten set screw (6).
  • Page 19 Water Flow For 3 Function Diverter / Flujo de agua para Desviadores de 3 posiciones / Écoulement de l’eau pour les inverseurs à 3 positions Outlet 1 Outlet 1 1st Position 2nd Position 3rd Position Outlet 1 Salida 1 Salida 1 posición posición posición...
  • Page 20 What You Must Do To Obtain Warranty Service or Replacement Parts: A warranty claim may be made and replacement parts may be obtained by calling 1 800 345 DELTA (3358) or by contacting us by mail or online as follows (please include your model number and date of original purchase): ©...
  • Page 21 IMPORTANT DOCUMENTS ENCLOSED CAUTION: To reduce the risk of injury due to hot water burns, make sure the enclosed labels are applied where specified on the label. DOCUMENTOS IMPORTANTES INCLUIDOS AVISO: Para reducir el riesgo de lesión por quemaduras de agua caliente , asegúrese que las etiquetas incluidas se han aplicado donde se ha especificado en la etiqueta.
  • Page 22 (such as when a dishwasher or washing machine is in use with this valve or call 1-800-345-DELTA. These valve series are designed to minimize the effects of while you are taking a shower). After installation, verify that the rotational limit stop or outlet water temperature changes due to inlet pressure changes, commonly caused by dishwashers, washing machines, toilets and the like.
  • Page 23 6 and if still uncertain, call us at WARNING: Do not install a shut-off device on 1-800-345-DELTA. either outlet of this valve. When this type of device shuts off the water flow, it can defeat...
  • Page 24 Delta Faucet Company may, in its sole discretion, use new, refurbished or recertified parts or products for such repair or replacement. If repair or replacement is not practical, Delta Faucet Company may elect to refund the purchase price in exchange for the return of the product. These are your exclusive remedies.
  • Page 25 ® MultiChoice Rough-In Installation (When your product requires) SHUT OFF WATER SUPPLIES. finished wall. Consider the type and thickness of your • Mount body using the two stringer finished wall before placing your stringer mounting holes (4) on the bracket. back plate.
  • Page 26 Copper Tubing Iron Pipe • Connect valve body to water supplies using If you are making a BACK TO BACK the proper fittings for your valve body type OR REVERSE INSTALLATION (hot on (copper tubing, iron pipe or Pex). Note: (1) right and cold on left) install the valve is the cold inlet port and (2) is the hot body as described, but the water supply...
  • Page 27 • Connect top outlet (1) to shower pipe with proper fittings. • Connect bottom outlet (2) to tub spout pipe with proper fittings. • Pipe (3) between valve body and tub spout must be a minimum of 1/2" (13 mm) copper pipe or 1/2"...
  • Page 28 Cartridge Installation Rotate valve cartridge (1) so the words Turn off water supplies. Remove bonnet “HOTTER COLDER” (2) appear on the top. nut (1) and test cap (2) from the body. If Insert cartridge assembly into rough-in body. this is not a thin wall mounting, the entire A light coating of plumbers grease applied to plasterguard (3) may be removed.
  • Page 29 Installation Shower Head and Tub Spout Installation FOR SHOWER HEAD INSTALLATION: Connect top outlet (1) to shower arm (2) with proper fittings. To prevent damage to finish on shower arm, insert wall end of shower arm into shower flange (3) before screwing arm into riser connection.
  • Page 30 FOR TUB SPOUT INSTALLATION: Refer to the installation instructions supplied with your spout. Do not connect deck mount spouts to in-wall valves. Do not use hand showers connected in lieu of a tub spout to a tub/shower valve. Do not use PEX tubing for tub spout drop.
  • Page 31 Adjusting the Rotational Limit Stop -For RLS With Removable Disc Hotter Disc Stem 1st Position IMPORTANT: The Rotational Limit Stop is used to limit the a comfortable bath or shower is typically amount of hot water available such that, if set between 90°F - 110°F.
  • Page 32 -For RLS With Pull/Turn Adjustment Hotter Cooler RLS with pull/turn adjustment IMPORTANT: The Rotational Limit Stop is used to limit the a comfortable bath or shower is typically between 90°F - 110°F. amount of hot water available such that, if set properly, a scald injury is less likely to occur if the •...
  • Page 33 Slide the sleeve over the cartridge, body and O-ring. Note: Adust for up to 1" thick wall. For thick wall installation, visit delta faucet website, check "view technical specification" of the models you bought, order the appropriate thick wall installation kit RP to get additional 1 3/4"...
  • Page 34 Install adapter (1) on cartridge stem (6) with screw (2). Thread set screw (4) into handle (3) slightly, put handle (3) on adapter (1) , hold and adjust the handle (3) at OFF position to ensure it well aligned with sleeve (7). Then tighten set screw (4).
  • Page 35 Cartridge Summary Reference Sheet ® Monitor Series 1300/1400 Cartridge shipped in July 2006 and after Cartridge shipped before March 2006. ® (prior to MultiChoice transition). Shorter lower Shorter lower housing housing White White Blue or off-white Blue Order RP19804 to replace cartridge. Order RP19804 to replace cartridge.
  • Page 36 107528 Rev. F...
  • Page 37 6 y si todavía no está seguro, llámenos al entrada son por los cambios estacionales. 1-800-345-DELTA. ADVERTENCIA: No instale un aparato de corte Después de hacer la instalación y el ajuste,...
  • Page 38 Para los fines de esta garantía, el término “aplicación residencial multifamiliar” se refiere a la compra del grifo a un vendedor autorizado de Delta por parte de un comprador que es propietario, pero quien no reside en la vivienda en la que se instaló inicialmente el grifo, como en una unidad individual alquilada o arrendada o en una vivienda unifamiliar de unidades múltiples (dúplex o casa adosada), o en un condominio, edificio de apartamentos o centro...
  • Page 39 ® Instalación de la plomería MultiChoice (Cuando su producto lo requiere) CIERRE LOS SUMINISTROS DE AGUA. rasante o secundario el 3/8”a la pared Considere el tipo y el grosor de su pared acabada. Instale la pieza usando los dos terminada antes de colocar su placa trasera agujeros de instalación del acoplamiento de acoplamiento de las tuberías.
  • Page 40 Tubería de Hierro Cobre Conecte el cuerpo de la válvula a los sumin- Si está hacienda una instalación dorso istros de agua usando los accesorios apro- con dorso o a la inversa (caliente en la piados para el tipo de su válvula (tubería de derecha y fría en la izquierda) instale el cobre, hierro o Pex).
  • Page 41 Instalación Conecte la salida de arriba (1) a la tubería de la regadera con los accesorios apropiados. Conecte la salida de abajo (2) a la tubería del surtidor de la bañera con los accesorios apropiados. La tubería (3) entre el cuerpo de la válvula y el de la bañera debe ser de un mínimo de 1/2"...
  • Page 42 Instalación del Cartucho Gire el cartucho de la válvula (1) de forma que Cierre los suministros de agua. Quite la las palabras "HOTTER COLDER" estén en la la tuerca tapa (1) y la tapa de prueba (2). Si parte superior. Inserte el cartucho en el cuerpo no es para instalar en pared delgada, puede de la tubería preliminar.
  • Page 43 Instalación de la Cabeza de la Regadera y el Surtidor de la Bañera PARA LAS INSTALACIONES DE LAS CABEZAS DE REGADERA: Conecte la toma de salida de agua superior (1) al brazo de la regadera (2) con los accesorios apropiados. Para prevenir daño al acabado del brazo de la regadera, introduzca el extremo que va hacia la pared del brazo de la regadera dentro del reborde (3) antes de atornillar el brazo en la conexión de...
  • Page 44 PARA LA INSTALACIÓN DEL SURTIDOR DE LA BACERA: Refiérase a las instrucciones para la instalación suministradas con su surtidor. No conecte los surtidores para las instalaciones en las superficies horizontales en las válvulas dentro de las paredes. No use las regaderas de mano en vez de un surtidor de bañera conectado a una válvula de bañera/regadera.
  • Page 45 El Ajuste del Tope que Limita la Rotación -Para RLS con Disco Extraíble Más Caliente Disco Unidad del Vástago Posición Primera IMPORTANTE: variadas en el agua de salida. Una temperatura El Ajuste del Tope que Limita la Rotación se de agua para un baño o ducha confortable típicamente es entre 90°F - 110°F.
  • Page 46 -Para RLS con Ajuste de Tracción/Giro MÁS FRÍA MÁS CALIENTE RLS con ajuste de tracción/giro. IMPORTANTE: temperatura del agua fría es más fría que durante el verano resultando en tem-peraturas El Ajuste del Tope que Limita la Rotación se variadas en el agua de salida. Una temperatura usa para limitar la cantidad de agua caliente de agua para un baño o ducha confortable disponible de manera que, si ajustado...
  • Page 47 O. Nota: Ajuste para paredes de hasta 1" de espesor. Para la instalación en pared gruesa, visite el sitio web de delta faucet, verifique "ver especificaciones técnicas" de los modelos que ha comprado, pida el juego de instalación...
  • Page 48 Instale el adaptador (1) en la espiga del cartucho (6) con el tornillo (2). Enrosque el tornillo de fijación (4) ligeramente en el mango (3), coloque el mango (3) en el adaptador (1), luego sostenga y ajuste el mango (3) en la posición OFF para asegurarse de que esté...
  • Page 49 Hoja resumen de referencia para el cartucho ® Monitor Series 1300/1400 El cartucho enviado en julio 2006 y después El cartucho enviado antes de marzo 2006. ® (antes de la transición a MultiChoice Más corto Más Más corto Más abajo Bastidor abajo Bastidor Blanco Blanco...
  • Page 50 107528 Rev. F...
  • Page 51 été effectués ou si la température et si cette ince rtitude persiste, appelez-nous au de l’eau d’alimentation a changé en raison du 1-800-345-DELTA. changement de saison. Après avoir terminé l’installation et le réglage, vous MISE EN GARDE – N’installez pas de dispositif devez inscrire, sur l’étiquette de mise en garde...
  • Page 52 Pièces et finis des robinets recertifiés Delta®: Delta Faucet Company offre en vente en ligne des robinets recertifiés Delta®. Les robinets recertifiés Delta® comprennent uniquement les robinets qui ont été certifiés à ce titre par Delta Faucet Company. Tous les pièces (autres que les pièces électroniques et les piles) et les finis de ces robinets Delta® recertifiés sont protégés contre les défectuosités de matériau et les vices de fabrication par une garantie qui est consentie au premier acheteur au détail et qui est d’une durée de dix (10) ans à...
  • Page 53 ® Installation de la plomberie brute MultiChoice (Lorsque votre produit nécessite) INTERROMPEZ L’ALIMENTATION EN EAU. fini. Installez le corps utilisez les deux Déterminez le type de la paroi et son trous (4) de la fixation qui donnent sur épaisseur totale avant de placer la plaque l’entretoise.
  • Page 54 Cuivre Raccorder le corps de robinet à la tuyauterie Dans le cas d’une installation dos à dos (cuivre, fer ou Pex). Note : (1) correspond ou inversée (eau chaude à droite et eau à l’entrée d’eau froide et (2) correspond à froide à...
  • Page 55 À l’aide des raccords appropriés, raccordez l’orifice supérieur (1) au tuyau de la douche et l’orifice inférieur (2) au tuyau du bec de baignoire. Le corps de robinet doit être relié au bec de baignoire par un tuyau de cuivre d’au moins 1/2 po (13 mm) ou un tuyau de fer d’au moins 1/2 po (13 mm).
  • Page 56 Installation de la cartouche Interrompez l’arrivée d’eau. Enlevez le Tournez la cartouche (1) de sorte que les mots l’écrou à portée sphérique (1) et le capuchon « HOTTER COLDER » (2) se trouvent sur le d’essai (2) du corps. Si vous n’installez dessus.
  • Page 57 Installation de la pomme de douche et du bec de baignoire INSTALLATION DE LA POMME DE DOUCHE : Raccordez la sortie supérieure (1) au tuyau d’alimentation de la pomme de douche (2) à l’aide des raccords appropriés. Pour éviter d’abîmer le fini du tuyau de la pomme de douche, introduisez le côté...
  • Page 58 INSTALLATION DU BEC DE BAIGNOIRE : Consultez les instructions d’installation fournies avec le bec. Ne raccordez pas à une soupape murale à un bec conçu pour être monté sur une plage. Ne raccordez pas une douche à main à la sortie d’un robinet de baignoire-douche prévue pour un bec de baignoire.
  • Page 59 Réglage de la butée anti-échaudage -Pour RLS avec disque amovible Plus chaude Disque Obturateurs 1ère Position IMPORTANT: en hiver qu’en été, ce qui peut entraîner une La butée antiéchaudage sert à limiter la variation de la température à la sortie du quantité...
  • Page 60 -Pour RLS avec réglage Tirer / tourner PLUS FROID PLUS CHAUD RLS avec ajustement retirer/retourner. IMPORTANT: l’eau d’alimentation change. Par exemple, la La butée antiéchaudage sert à limiter la température de l’eau froide est plus basse quantité d’eau chaude disponible de sorte en hiver qu’en été, ce qui peut entraîner une Une blessure par échaudage est moins variation de la température à...
  • Page 61 Remarque: Veuillez ajuster pour un mur jusqu'à l'épaisseur de 1". Pour une installation sur un mur épais, veuillez visiter le site Web delta faucet, et consulter «Voir les spécifications techniques» des modèles achetés, et commander le kit d'installation RP approprié...
  • Page 62 Veuillez installer l'adaptateur (1) sur la tige de la cartouche (6) avec la vis (2). Veuillez visser légèrement la vis de réglage (4) dans la poignée (3), mettre la poignée (3) sur l'adaptateur (1), maintenir et régler la poignée (3) en position OFF pour vous assurer qu'elle est bien alignée avec le manchon (7).
  • Page 63 Fiche de référence sommaire de la cartouche ® Monitor Series 1300/1400 Cartouche expédiée en juillet 2006 et par la suite (avant Cartouche expédiée avant mars 2006. la transition à MultiChoice ® Logement inférieur Logement inférieur plus court plus court Blanc Blanc Bleu ou blanc...
  • Page 64 Notes/Notas/Notes 107528 Rev. F...
  • Page 65 Notes/Notas/Notes 107528 Rev. F...
  • Page 66 Delta Faucet Company Product Service 55 E. 111th Street Indianapolis, IN 46280 107528 Rev. F...