Télécharger Imprimer la page

Progress Lighting P85-TG Instructions De Montage Et D'installation

Publicité

Liens rapides

7
12 13
FIG.2
11
10
6
20
15
FIG.3
3
20
9
FIG.6
13
15
16
17
FIG.4
19
16
13
23
FIG.1
11
9
24
14
21
4
16
22
WHITE SUPPLY
WHITE OR IDENTIFIED
WIRE
FIXTURE WIRE
UL LISTED
WIRENUTS
BLACK SUPPLY
PLAIN OR BLACK
WIRE
FIXTURE WIRE
BARE, OR GREEN
BARE, OR GREEN
GROUND WIRE
FIXTURE GROUND
FROM SUPPLY
WIRE
FIG.5
PAGE
4
of
4
SPEC.NO.
022176 Rev. B
8
WARNING: RISK OF FIRE: Recessed portions of recessed housing, other than at point of support, shall be
spaced at least ½" from combustible material. Thermal insulation shall not be installed within 3" of the
recessed housing, or junction box, and shall not be so installed above fixture as to entrap heat, and prevent
the free circulation of air.
WARNING: If any special control devices are used with this fixture, follow the instructions carefully to assure
full compliance with N.E.C. requirements. If there are any questions, contact a qualified electrical contractor.
WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects,
and/or other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise
touching this product.
CAUTION: National Electrical Code, Article 110-3 (b), states that "Listed or labeled equipment shall be used or
installed in accordance with any instructions included in the listing or labeling". Use only Progress UL listed
trims. Use of other trims not listed in this fixture, including those that are UL classified, is a violation of N.E.C.
110-3 (b) and voids all warranties.
Follow this instruction sheet carefully. Be sure electricity is OFF before starting installation.
1. For Wooden Joists: Use the Centering Notches (4) located on the Plaster Frame to position the Fixture.
Extend the Bar Hangers (6), use joist alignment tabs to locate fixture and hammer the 4 Nails (7) into Joists (8)
14
(Fig. 1). Drive additional nails through holes in Bar Hanger for alternate support if required.
2. For Suspended Ceilings: Place the Fixture on the ceiling grid with the "T" Bars (9) running through the Bar
Hanger Notches (10). Using a flat head screwdriver or other tool, bend the integral t-bar mounting tabs (11)
downward to a vertical position (Fig. 3). Secure housing to the support structure with tie wire (supplied by
others) in the holes supplied. Sheetmetal screws (supplied by others) can also be used in the holes supplied
(20).
3. Locate Housing along Bar Hanger in desired position and, using pliers, squeeze the 4 Locking Tabs (12) on
the Plaster Frame (13) tightly over the Bar Hangers to prevent further Housing movement. Bar Hangers (6)
may be installed in alternate Slots (23) if mounting conditions require.
4. As desired, hanger bars (6) may be shortened at score mark to fit tight mounting conditions and joist
alignment tabs removed to adjust vertically as needed by breaking off with pliers.
5. Unsnap Junction Box Cover (14) by lifting the Leaf Spring (24).
6. Run supply wires through UL Listed connectors (not supplied) in one of the five Pryouts (15) on the Junction
Box (16) or Type NM cable (ROMEX) through an Opening above the Wire Retaining Plate (17). Connect
Supply Wires (19) as shown in Fig 4 & 5. Replace Cover.
8. Loosen Screws (21) to adjust Housing (3) for variations in ceiling thickness. Bottom of Housing should be
flush with ceiling (22) within tolerance.
9. Select a Trim from the Wattage Label inside the Housing. Use Only Lamp Types approved for the Trim
chosen. DO NOT EXCEED MAXIMUM LISTED WATTAGE(S)!
INSTRUCTION SHEET MUST BE REMOVED FROM FIXTURE PRIOR TO ENERGIZING.
10-03-12
Assembly & Installation Instructions
CAUTION:
Read instructions carefully and turn electricity off at main
circuit breaker panel before beginning installation.
P85-TG
(Ceiling Opening is to be 5-1/4" in Diameter)
PAGE
1
of
4
SPEC.NO.
022176 Rev. B
10-03-12

Publicité

loading

Sommaire des Matières pour Progress Lighting P85-TG

  • Page 1 CAUTION: Read instructions carefully and turn electricity off at main circuit breaker panel before beginning installation. P85-TG 12 13 WARNING: RISK OF FIRE: Recessed portions of recessed housing, other than at point of support, shall be spaced at least ½” from combustible material. Thermal insulation shall not be installed within 3” of the FIG.2...
  • Page 2 Se puede le Nécessaire de Joint Progress Lighting P8587-01 (acheter séparément). (Voir Fig. 2). usar el Kit de Junta Progress Lighting P8587-01 (comprar por separado). (Vea Fig. 2). FILS DE COURANT...