nVent RAYCHEM HWAT-ECO-GF Manuel D'installation, D'utilisation Et D'entretien page 22

Masquer les pouces Voir aussi pour HWAT-ECO-GF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Boiler low
temperature
EN
limit
FR
Boiler high
temperature
limit
Pipe sensor
Pipe sensor
low
temperature
limit
Pipe sensor
high
temperature
limit
E
02:14 p.m.
EXT
131°F
CONOMY TEMP
AT 05:00 p.m.
BOILER
140 °F
14 : 17
Language
Country
Voltage
Units of
14 : 17
Measure
Date
Time
Alarm buzzer
14 : 17
R2
Saving time
Time format
C
|
22
nVent.com/RAYCHEM
You can determine the low temperature limit. If the
boiler temperature reaches this value, the unit will
switch off the heating system in order to fulfil hygienic
requirements and avoid energy waste.
You can determine the high temperature limit.
If this value is reached the unit will switch off
the heating system to avoid scalding.
Activate/deactivate a connected pipe sensor by pressing
ON/OFF. The pipe sensor monitors the pipe temperature
and needs to be installed close to the furthest point in
the pipe distribution network.
You can determine the low temperature limit.
When the value is reached a warning will appear on the
screen but will not interrupt the unit's functioning. The
info status screen will show the actual pipe temperature.
You can determine the high temperature limit.
A warning will appear on the screen when the value is
reached and the unit will switch off the heating system to
avoid scalding.
General Settings
GENERAL SETTING
SELECT LANGUAGE
SELECT COUNTRY
SELECT VOLTAGE
SELECT UNITS OF MEASURE
SELECT DATE
SELECT TIME
Choose your language from the language menu.
WATER TEMP. & PROGRAM
Select a country in this menu. Your selection defines
SELECT WATER TEMPERATURE
the default values used for time format.
SELECT PROGRAM
Choose the suitable voltage in this menu.
PROGRAM TIMER
Choose your desired units of measure Metric (mm, °C) or
Imperial (in, °F).
Use the up/down arrow keys to select the year.
After a power break of more than 10 days you need to
re-enter the date.
Use up/down arrow keys to set hour and minute.
After a power break of more than 10 days you need to
re-enter the time.
Alarm sound will go off inside the unit indicating an error
condition. Activate/deactivate the alarm sound by
pressing ON/OFF. Note: Alarm messages and an alarm
signal will be created any time in case of a malfunction.
Activate/deactivate the daylight saving time function by
pressing ON/OFF.
Choose your desired time format, 12H or 24H.
14 : 17
ENGLISH
UNITED STATES
240V
IMPERIAL
01.01.2022
14:17
14 : 17
131°F/122°F
HOTEL