INSTALLATION INSTRUCTIONS
Note: Wires connecting between box(es) and from transformer must be
protected from abrasion, and being pulled at connections. They also may have
to be fished through at a later stage of construction. Depending on installation,
the cable bushings included may be replaced by installer supplied 1/2" conduit.
Rough-in box as per Figure 1.
Note: Conduit can be permanently bent to hold shape.
The transformer is to be installed in an adjacent accessible space. (DO NOT
install the transformer inside the control box.) Cable from the transformer
to the driver board/controller may be roughed in at this time depending on
installation. Use cable which complies to local electrical codes for a 1 amp load.
FOR PROXIMITY
MODELS:
®
Use 3-conductor 18 AWG (18/3) wire between the transformer and this
recessed enclosure.
FOR ALL OTHER MODELS:
Use 2-conductor 18 AWG (18/2) wire between the transformer and this
recessed enclosure.
HARDWIRE OR BATTERY: If recessed box is supplied, rough in as per Figure
1. The most vandal resistant installation is when the control box is as close to
the bottom of the sink as feasible. For wall hung sink installation, sensor conduit
rough in should be directly under the basin to minimize sensor cord exposure.
Rough in drainage. Rough in water supply to 10" control box inlets and to spout
connection. Finish walls. Valve spacer is for temporary use only for flushing of
system.
Must be replaced with solenoid (Fig. 2 & 3).
FLUSH SYSTEM/SET TEMPERATURE
Remove coverplate from control box. Open screwdriver stop(s) to flush
installation for 1 minute minimum.
A.
Run water for a sufficient time so the hot and cold water supplies are as
hot and cold as they will get.
B.
Thermostatic Mixing Valve (Fig. 3). To adjust the mixed outlet temperature
of the valve, remove the cap to gain access to the adjusting spindle. The
spindle should be rotated towards the "C" side to reduce the temperature
and towards the "H" side to increase the temperature - until the desired set
point is reached (refer to Fig. 4).
Periodic Inspection/Maintenance - We recommend that
this valve is checked at least once per year to ensure its
continued function. For installations with poor or unknown
water quality, or other adverse supply conditions, it may be
necessary to check the valve at more frequent intervals.
The temperature should be checked at the same outlet
as was used for commissioning in the first instance. If the
temperature is more than 3°F from the commissioning
in temperature, refer to the included Maintenance and
Installation Guide.
C.
Close stop(s).
(Do not over torque stop).
Fig. 4
Towards
"H" side to
increase
Towards
temperature
"C" side
to reduce
temperature
TMV Repair Kit
061137A - Adjustment Wrench
063164A - Check Valves (2/pkg)
Installation should be in accordance with local
plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE
INSTALLATION.
Remove suitable knockout(s) in box(es) and insert
cable bushing(s).
Fasten box to
framing using
holes provided
inside of box
Control Box
Rough-in box
to be installed
(flush to 1/4")
to finished wall
*
The rough 10" cover plate is intended for temporary use only and must be
replaced with permanent 12" plate after rough-in stage is complete.
The 12" permanent plate is included on the applicable "Trim" models.
If a "Trim" model was not ordered, repair parts 060577A (12" permanent plate)
and 060073A (4 screws & driver bit) must be ordered separately.
Control Box #1
063135A
Stop
Inlet:
1/2" Sweat
www. s p e c s e l e c t . c o m
ELAVT0001ARI
ELAVT0008ARI
Finished
Wall
Flexible, Sensor
Cord Conduit
1/2" sweat connection
257mm
305mm (12")
(10.13")
Stainless Steel
Cover Plate
102mm (4")
Control Box #8
Fig. 2
Flexible Sensor Cord
Conduit (supplied on
Hot Inlet
Recessed Mount Box)
1/2" Sweat
1/2" Sweat
Outlet
Tempered Water
(By Others)
Fig. 1
356mm
(14")
SUPPLIED:
max.
1/2" Sweat
Outlet from Box
BALANCE BY OTHERS
*
Product supplied as
shown by solid lines.
All items shown by
dotted lines supplied
by other or Trim
Package.
Fig. 3
Flexible Sensor Cord
Conduit (supplied on
Recessed Mount Box)
Cold Inlet
1/2" Sweat
1/2" Sweat
Outlet
063135A
Stops
063179A
Thermostatic Mixing Valve
with checks and gaskets
210837 Rev. A

Publicité

loading

Sommaire des Matières pour Delta ELAVT0001ARI

  • Page 1 Installation should be in accordance with local ELAVT0001ARI plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE ELAVT0008ARI INSTALLATION. Remove suitable knockout(s) in box(es) and insert cable bushing(s). INSTALLATION INSTRUCTIONS Fig. 1 Note: Wires connecting between box(es) and from transformer must be protected from abrasion, and being pulled at connections.
  • Page 2 L’installation doit être conforme aux Codes de ELAVT0001ARI plomberie et d’électricité locaux. VIDER SOIGNEUSEMENT TOUS LES TUYAUX ELAVT0008ARI AVANT DE PROCÉDER À L’INSTALLATION. Enlevez les entrées défonçables requises et insérer les bagues de cable. INSTRUCTIONS D’INSTALLATION Fig. 1 Remarque : Les câbles mis en circuit entre le ou les boîtiers et du transformateur doivent être protégés contre l’abrasion et tirés aux endroits où...
  • Page 3 Delta Commercial Faucet Limited Warranty All parts of the Delta® HDF® and TECK® faucets are warranted to the original consumer purchaser to be free from defects in material, finish and workmanship for a period of five (5) years unless otherwise specifically stated in the catalogue and price book.

Ce manuel est également adapté pour:

Elavt0008ari