INSTALLATION INSTRUCTIONS
Note: Wires connecting between box(es) and from transformer
must be protected from abrasion, and being pulled at connections.
They also may have to be fished through at a later stage of
construction. Depending on installation, the cable bushings
included may be replaced by installer supplied 1/2" conduit.
Rough-in box as per Figure 1.
The transformer is to be installed in an adjacent accessible
space. (Do NOT install the transformer inside the control
box.) Cable from the transformer to the driver board/controller
may be roughed in at this time depending on installation. Use
cable which complies to local electrical codes for a 1 amp load.
No. 18 is usually sufficient.
HARDWIRE OR BATTERY
: If recessed box is supplied, rough
in as per Figure 1. The most vandal resistant installation is when
the control box is as close to the bottom of the sink as feasible.
For wall hung sink installation, sensor conduit rough in should be
directly under the basin to minimize sensor cord exposure.
Rough in drainage. Rough in water supply to 10" control box
inlets and to spout connection. Finish walls.
Valve spacer is for temporary use only for flushing of system.
Must be replaced with solenoid (Fig. 2 & 3).
FLUSH SYSTEM/SET TEMPERATURE
Remove coverplate from control box. Open screwdriver stop(s)
to flush installation for 1 minute minimum.
A Run water for a sufficient time so the hot and cold water
supplies are as hot and cold as they will get.
B Thermostatic Mixing Valve (Fig. 3).
To adjust the mixed outlet temperature of
the valve, remove the cap to gain access
to the adjusting spindle. The spindle
should be rotated towards the "C" side to
reduce the temperature and towards the
"H" side to increase the temperature - until
the desired set point is reached (refer to
Fig. 4).
Periodic Inspection/Maintenance - We
recommend that this valve is checked at least
once per year to ensure its continued function.
For installations with poor or unknown water
quality, or other adverse supply conditions, it
may be necessary to check the valve at more
frequent intervals. The temperature should be
checked at the same outlet as was used for
commissioning in the first instance. If the
temperature is more than 3°F from the comm-
issioning in temperature, refer to the included
Maintenance and Installation Guide.
C Close stop(s).
Fig. 4
Towards
Towards
"C" side
"H" side to
to reduce
increase
temperature
temperature
TMV Repair Kit
061137A - Adjustment Wrench
Installation should be in accordance with local
plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE
INSTALLATION.
Remove suitable knockout(s) in box(es) and insert
cable bushing(s).
Fasten box to
framing using
holes provided
inside of box
257mm
(10.13")
Control Box
Rough-in box
to be installed
(flush to 1/4")
to finished wall
*
The rough 10" cover plate is intended for temporary use only and must be replaced
with permanent 12" plate after rough-in stage is complete.
The 12" permanent plate is included on the applicable "Trim" models.
If a "Trim" model was not ordered, repair parts 060577A (12" permanent plate) and
060073A (4 screws & driver bit) must be ordered separately.
Control Box #1
Flexible Sensor
Cord Conduit
(supplied on Recessed
Mount Box)
Outlet
3/8" M.I.P.
063135A
Stop
w w w . s p e c s e l e c t . c o m
ELAVT0001RI
ELAVT0008RI
Finished
Wall
Flexible, Sensor
Cord Conduit
3/8" MIP Outlet from Box
3/8" Compression Joint at Spout
BALANCE BY OTHERS
305mm (12")*
Stainless Steel
Cover Plate
102mm (4")
Fig. 2
Control Box #8
Hot
Tempered Water
(By Others)
Inlet:
063135A
1/2" Copper
Stops
Fig. 1
355mm
(14")
SUPPLIED:
max.
Product supplied as
shown by solid lines.
All items shown by
dotted lines supplied
by other or Trim
Package.
Fig. 3
Flexible Sensor
Cord Conduit
(supplied on
Recessed Mount Box)
Inlets 1/2"
Copper
Outlet
3/8" M.I.P.
Cold
063136A
Thermostatic Mixing Valve (with checks)
210330 Rev. A

Publicité

loading

Sommaire des Matières pour Delta ELAVT0001RI

  • Page 1 Installation should be in accordance with local ELAVT0001RI plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE ELAVT0008RI INSTALLATION. Remove suitable knockout(s) in box(es) and insert cable bushing(s). INSTALLATION INSTRUCTIONS Fig. 1 Note: Wires connecting between box(es) and from transformer must be protected from abrasion, and being pulled at connections.
  • Page 2 ELAVT0001RI L’installation doit être conforme aux Codes de plomberie et d’électricité locaux. VIDER SOIGNEUSEMENT TOUS LES TUYAUX ELAVT0008RI AVANT DE PROCÉDER À L’INSTALLATION. Enlevez les entrées défonçables requises et insérer les bagues de cable. INSTRUCTIONS D’INSTALLATION Fig. 1 Remarque : Les câbles mis en circuit entre le ou les boîtiers et du transformateur doivent être protégés contre l’abrasion et tirés aux...