V1.0
IMMERSE STRAINER BASKET
The strainer basket must be fully immersed into the water source to ensure that air
is not introduced into the pump. Place the strainer basket at a sufficient depth that
the pumping system will not drain enough water to uncover the strainer basket.
To keep silt or sand from the bottom of a
lake, river or ditch from entering the
suction hose, anchor the strainer basket on
a solid surface such as group of rocks, or
place it in a bucket sitting on the bottom.
STARTING THE PUMP
PRIME THE PUMP
CAUTION! Do not touch an operating engine. They are designed to operate at
high temperatures and may inflict a burn injury.
IMPORTANT! Pump must be primed. Make sure pump is full of water before
running. Failure to do so will damage to the pump.
1.
Remove priming plug from top
of pump.
2.
Fill pump with clean, clear water up
to top of discharge outlet.
3.
Replace priming plug.
Visit www.princessauto.com for more information
2 in. Gas Water Pump
8887200
Fig. 6
Fig. 7