FOR SERVICE TECHNICIAN'S USE ONLY
1.
Enter Diagnostics Mode.
2.
Touch or scroll to "Sensors & Switches" in the Diagnostics menu, and
then touch "OK."
3.
Touch or scroll through the Sensors & Switches menu to view the desired
status.
NOTE: Touching "Back" will return the display to the main Diagnostics
Menu.
General Procedure: System Information
NOTE: This procedure is to view the following system information:
System Information
Display
Model #
Model Information
Serial #
Product Serial Number
UI Serial #
User Interface Serial Number
UI Version
User Interface Software Version
HMI Central SW
HMI Central Board Software Version
HMI Left SW
HMI Left Keyboard Software Version
HMI Left EE
HMI Left Keyboard EEPROM Version
HMI Right SW
HMI Right Keyboard Software Version
HMI Right EE
HMI Right Keyboard EEPROM Version
Kernel Version
HMI Central Board Software Version
Touch Calibration
LCD/TP FPC Tail Software Version
Version
Database Version
HMI Central Board Database Structure
Audio Version
HMI Central Board Software Version
Microwave Oven Appliance Control Unit Software
MWO ACU SW
Version
Diagnostics Entries
Number of times Diagnostic Menu has been entered
1.
Enter Diagnostics Mode.
2.
Touch or scroll to "System Information" in the Diagnostics menu, and
then touch "OK."
3.
Touch or scroll through the System Information menu to view the desired
status.
NOTE: Touching "Back" will return the display to the main Diagnostics
Menu.
General Procedure: Model Selection
NOTE: When a new User Interface is installed, you will be prompted to select
a new model number upon power up. To change the model number on an
existing user interface, follow the steps below.
1.
Enter Diagnostics Mode.
2.
Touch or scroll to "System Information" in the Diagnostics menu, and
then touch "OK."
3.
Touch or scroll to "Model Number," and then touch "OK."
4.
Touch or scroll to the correct model number in the list, and then touch
"Select."
6