GYS Powerduction 110LG Mode D'emploi page 13

Masquer les pouces Voir aussi pour Powerduction 110LG:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Translation of the original instructions
2. Connect the product cable to the front panel of the Powerduction.
3. The Powerduction Heat Controller is connected. Select an operating mode.
OPERATION WITH 2 THERMOCOUPLES (SUPPLIED) (FIG I)
Set the switch (8) to ON and press the heater enable button (9) (pedal activation).
Connect the supplied thermocouples to the side of the interface:
Thermocouples should be installed as close as possible to the area under the inductor ferrite.
It is recommended to drill the workpiece below the area to be heated with a drill bit of diameter 2 to a depth of about
1 to 2mm.
If switches (1) and (2) are in the OFF position, the Powerduction Heat Controller displays the highest measurement on
the Powerduction 110/160/220LG.
OPERATION WITH A PYROMETER (ref. 064119) (FIG I)
1. Set switches (2), (7) and (8) to ON.
2. Connect a thermocouple (supplied) to a thermocouple thermometer (not supplied).
3. Connect the pyrometer to the Powerduction Heat Controller (2 connectors)
When plugging the pyrometer, observe the connection direction of the thermocouple connector.
The positive terminal of the connector should be towards the front of the Powerduction Heat Controller,
the negative terminal towards the rear.
4. Install the pyrometer on the Powerduction 110/160/220LG lance using the adapter and nylon screws provided.
5. Install the thermocouple on the part to be heated as close as possible to the ferrite of the inductor (it is recom-
mended to drill the part below the area to be heated with a 2 mm diameter drill to a depth of approximately 1 to
2 mm to insert the thermocouple).
POWERDUCTION HEAT CONTROLLER
+
-
+
-
EN
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Powerduction 160lg

Table des Matières