To configure a setup for Photogate and Smart Pulley
u
1. On the E-CON3 main menu, press 1(SET) 1(WIZ) to start the setup wizard.
2. This displays the "Select Sensor" dialog box.
3. If you are using a Vernier Photogate with Pulley, select [VERNIER] - [Photogate] -
[Pulley]. When the "Select Channel" dialog box appears, advance to step 4 of this
procedure.
If you are using a CMA Photogate with Pulley, select [CMA] - [Photogate] - [Pulley]. When
the "Input Distance(m)" dialog box appears, advance to step 5 of this procedure.
4. Press 1(CH1) or 2(SONIC) to specify the channel where the Photogate is connected.
• This displays the "Input Distance(m)" dialog box.
5. On the "Input Distance(m)" dialog box, input a value in the range of 0.1 to 4.0 and then
press w.
6. Perform step 10 (in the case of a Vernier Photogate) or steps 9 and 10 (in the case of a
CMA Photogate) under "To configure a Data Logger setup using Setup Wizard" (page
2-2).
k Outputting the Waveform of a Function through the Speaker
(EA-200 only)
Normally, the Setup Wizard helps you configure setups for sensors connected to a Data
Logger. If you select [CASIO] - [Speaker] - [y=f(x)] on the "Select Sensor" screen, however, it
configures the EA-200 to output the sound that corresponds to a function that you input and
graph on the calculator.
To configure a setup for speaker output
u
1. Connect the data communication cable (SB-62) to the communication port of the
calculator and the MASTER port of the EA-200.
2. Perform the first two steps of the procedure under "To configure a Data Logger setup
using Setup Wizard" on page 2-2.
3. On the "Select Sensor" screen, select [CASIO] - [Speaker] - [y=f(x)].
This displays a screen like the one shown below.
4. Press w to advance to the View Window setting screen.
• The following settings are configured automatically: Ymin = –1.5 and Ymax = 1.5. Do not
change these settings.
5. Press w or J to advance to the graph function list.
2-6
Using the Setup Wizard