Technical data
Heater
ECE Type Approval Number
Kind of construction
Heating flow (at ambient temperature of 20°C)
Fuel
Fuel consumption
Rated voltage
Operating voltage range
Rated power consumption at 24V *
Max. permitted temperature of sucked
combustion air
Permitted ambient temperature during operation °C
Permitted storage temperature
Permitted operating overpressure
Capacity of the heat exchanger
Minimum water flow **
Minimum capacity of the water system
CO
in exhaust gas at rated voltage
2
Heater dimensions (tolerance ± 3 mm)
Weight
*
without circulating pump
** Minimum water flow at coolant temperatures above 50°C
Below 50°C a lower water flow is permitted, if the occurence of vapor bubbles due to local overheating safely can be excluded.
56
Thermo plus 230
E1 122R 00
0466
kW
23
(kcal/h)
(20 000)
kg/h
2.5
V =
V =
W
60
°C
°C
bar
l
l/h
1900
l
Vol %
9.0 + 1.5
mm
kg
Thermo plus 230/300/350
Thermo plus 300
0467
High pressure atomizer
30
(26 000)
Diesel / Heating oil
3.0
24
20.5 ... 30
90
+ 85
-40...+ 100
-40...+ 110
max. 2.0
1.8
2400
25
9.5 + 1.5
Length 540 / Width 250 / Height 222
16.8
Thermo plus 350
0468
35
(30 000)
3.6
120
2700
9.5 + 1.5