Technical Data - Valeo THERMO PLUS 230 Notice De Montage

Masquer les pouces Voir aussi pour THERMO PLUS 230:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Thermo plus 230/300/350
14

Technical data

Except where limit values are specified, these technical data refer to the
usual heater tolerances of ±10% at an ambient temperature of +20°C
and at the rated voltage.
NOTE:
The assignment of circulating pumps to heaters must be made consider-
ing the water-side resistances.
14.1. Fuel
Suitable fuel is the diesel fuel specified by the vehicle manufacturer.
The following table lists the by Valeo approved fuels and their specifica-
tions.
Requirements
Fuel
acc.
Summer Diesel
DIN EN 590
Winter Diesel
DIN EN 590
Arctic Diesel and Diesel
DIN EN 590
for a strong winter climate
*
Bio Diesel (FAME)
DIN EN 14214
Paraffinic diesel fuel from
DIN EN 15940
synthesis or hydro-gena-
*
tion (HVO)
*
Further information on approved fuels contains the TI (Technical
Information) Fuels.
It can be found on the Valeo homepage under Service/Technical Up-
dates (TI)/Heating systems.
In case of air temperatures below 0°C a commercially available winter
Diesel fuel, at temperatures below -18°C a Diesel for arctic climate
conditions must be used.
The usage of flow improvers respectively additives is permitted. There
are no negative influences due to additives known.
Remarks
ATTENTION:
While using the fuels, their operating limits must be considered
and if necessary, suitable measures (nozzle preheating, electrical
heated filter) should be applied.
If fuel is supplied from the vehicle tank, follow the vehicle manufac-
max. 20%
turer's instructions on additives.
see TI Fuels