Table III–Recommended Fusing Data, 115 Volt 60 Hz Motors.
Pump
Motor
Model No.
H.P.
JWPA5DC-2A3
JWPA5EC-2A3
JWPS5FC-2A3
1-1/2SPL
17290-J1002 (2-Speed)
1 – 1/6
NOTICE: Values given are for pump motor only. Do not put
any other accessories on this circuit.
Table IV–Recommended Fusing Data, 115 Volt 60 Hz Single
Speed Motors.
Pump
Motor
Model No.
H.P.
JWPA5DL-2A1, -2A2
JWPA5EL-2A1, -2A2
JWPAS5F-2A4U
1-1/2 SPL
JWPA5FL-2A1, -2A2
1-1/2
Table V–Recommended Fusing Data, 230 Volt 60 Hz Motors.
Pump
Motor
Model No.
H.P.
JWPA5E-230A2
Table VI–Recommended Fusing Data, 115 Volt 60 Hz 2-Speed
Motors.
Pump
Motor
Model No.
H.P.
JWPA5YEL
1 / 1/8
JWPA5YFL
1-1/2 / 1/6 16.6/3.6
NOTICE Values given are for pump motor only. Do not put any
other accessories on this circuit.
NOTICE: Determine circuit breaker rating from Table III, above.
Determine correct outlet required from illustration below.
JWP 3/4 and 1 HP Models with
3/4 and 1 HP Models with
-2A2 and -A2U suffix and
–A2 suffix use15-amp
1-1/2 HP Models with -2A4U
straight outlet, above.
suffix use 15-amp straight
outlet, above.
Branch
Full Load
Circuit Breaker
Amps
Rating (Amps)
3/4
9.4
15
1
11.9
15
11.9
15
11.6/3.3
15
Branch
Full Load
Circuit Breaker
Amps
Rating (Amps)
3/4
9.0
15
1
12.0
15
12.0
15
16.0
20
Branch
Full Load
Circuit Breaker
Amps
Rating (Amps)
1
6.1
15
Branch
Full Load
Circuit Breaker
Amps
Rating (Amps)
11.7/3.39
15
25
JWP 1-1/2 HP Models with
1-1/2 HP Models with
-2A2 and A2U suffix use
–2A2 suffix use 20-amp
20-amp straight outlet, above.
straight outlet, above.
Startup/Operation
Hazardous suction. Can trap and tear hair
or body parts and can cause drowning. Do not block
pump suction. Small children using pool must ALWAYS
have close adult supervision.
Valve Setting
Valve Setting
Figure 8
All JWP Models with
All models with –A1 or
-2A1 suffix use 20-amp
–2A1 suffix use 20-amp
twist-lock outlet, above.
twist-lock outlet, above.
8
(See Figure 9)
Purpose/Flow
FILTER
Normal filtration and
vacuuming; water goes
through filter to pool.
RINSE
For initial startup cleaning
and sand bed leveling
after backwash; water goes
through filter to waste.
RECIRCULATE
Circulates pool water;
bypasses filter.
737 0294
Purpose/Flow
BACKWASH
Reverses flow for
cleaning; water
goes through filter
to waste.
CLOSED
Shuts off all flow to
filter and pool.
WINTERIZE
Leaves all valve ports
partially open for
winter storage.
738 0294