12.1.1 Analogue Video connection
Even if not strictly necessary to complete
configuration, the procedure indicated below
requires connection of a CCTV tester (or a standard
monitor) for Video output of the Ulisse unit used to
check correct setup.
Switch off the power supply and unscrew the cover
from the base using a 4 mm Allen wrench.
Lift the cover and connect a co-axial cable to the
video terminals.
Fig. 94
The co-axial cable must enter the base via
the cable gland; on the contrary, the cover
cannot be re-installed on the base.
Install the cover again on the base and switch on the
device power supply.
The start passages should be displayed on the CCTV
test if correctly connected.
It is not possible to display the video from
the network camera using the analogue
video output.
12.1.2 Camera connection
Switch off the power supply and open the cover of
the housing to access the camera board and the
housing.
46
Modify the electrical connections of the camera as
indicated in the following figures.
Fig. 95
GND
VIDEO
Fig. 96
As planned by RS485 mode, the camera controls
Pan & Tilt via the serial line. Therefore, you need
to connect the RS485 output of the camera to the
telemetry port of the Ulisse unit, using the serial line
coupled to the UTP network cable (Fig. 97, page 46).
Fig. 97
+12V GND
CN7. ONVIF mode
+12Vdc GND
CN7. RS485 mode
MNVCUPTMAXIR_2104_EN
+12V
GND
A
B
F1
F2
+12V
GND
A
B
F1
F2