11
ADJUST SUPPLY STOP; Fig. 13
IMPORTANT: To avoid overflowing, the SUPPLY STOP (3)
must never be opened to the point where the flow from
the valve exceeds the flow capacity of the fixture.
Valve is designed to provide stated flush volume with a
25 gpm flow rate for toilet and 10 gpm flow rate for urinal.
1. Remove COVER (2) from SUPPLY STOP (3).Turn on
water supply 1/4 turn to 1/2 turn(CCW) and test for leaks.
Note: Unit may flush for approximately 5 to 10 sec. when
water is first turned on.
2. Push down on HANDLE (4) to initiate flush.
3. Adjust SUPPLY STOP (3) after each flush until the
stated flush volume is achieved, no splashing occurs
and the fixture is properly cleansed.
4. When adjustment is complete, reinstall COVER (2)
and tighten to ensure vandal-resistance.
12
HOW TO RETROFIT OUR VALVE; Fig. 14
(Replaces Industry Standard Manual and Electronic
Valves)
Note: In most Retrofits the wall escutcheon, supply
stop, cover tube and vacuum breaker do not have to
be replaced. If these items do need replacement they
must be purchased separately or order the complete
flush valve assembly from American Standard.
1. Remove COVER (1) from SUPPLY STOP (2) if installed.
Fig. 14.
2. Turn water supply off. Fig. 14.
3. Unthread COUPLING NUT (3) and VACUUM BREAKER
COUPLING NUT (4). Remove FLUSH VALVE (5).Fig. 4a.
4. Clean all threaded connections before installing the new
flush valve. Fig. 14a.
5. Refer to Sections 4, 5 and 6 to complete the retrofit
installation. Fig. 14b.
13
LEFT OR RIGHT HAND INSTALLATION;
Fig. 15
1. The FLUSH VALVE can be installed either as a right
or left hand installation.
2. Orientate the FLUSH VALVE as shown in Fig. 13 to
desired position for a left or right hand installation.
Fig. 13
Fig. 14
5
2
1
3
4
Right or Left Hand Installation
Fig. 15
Left Hand
7
REMOVE COVER
3
COUNTER-CLOCKWISE
OPENS CONTROL STOP
CLOCKWISE CLOSES
CONTROL STOP
Fig. 14a
Fig. 14b
CLEAN
CONNECTIONS
Right Hand
M965890 Rev. 1.1 (1/19)
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ultima 6147sm

Table des Matières