FTE Maximal GENIUS 10 Lte Manuel D'utilisation page 30

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
1.- No Error Detected: The programmed channels will be able to arrive to the selected value in the "Output Level"
option. In case in the "Prog CH" menu some of the filters have been configured as digital ones, the output level of these
filters will be 2 dB lower than the fixed value in "Output Level" option.
2.- Errors Detected: The results of the autoleveling appear in the display, showing the filters which can arrive to the
indicated value (with an "O"), and the filters that couldn't reach this level (with an "X").
Example:
At the example above, the filters 8 and 9 would have problems and they couldn't we adjusted to the level shown in the
"Output Level" option. This problem could be dared because of having an excess of level, or not having level enough.
In case of having filters with errors in "Autoleveling" process, go to "Prog CH" menu in order to verify that there are no
errors in the programming of the filters with errors, and correct the existing error. In case the filters are well
programmed, it would indicate that due to the input level at those channels, it will be not possible to reach the indicated
"Output Level" value.
Before starting the AUTOLEVELING, it is NECESSARY disconnecting the AUX input, otherwise the
measurements that the equipment carries out, could be false due to the channels of this input.
- AGC: This option allows activating or deactivating the Automatic Control Gain. You must take into account that when
this function is enabled, acceding to the programming menu of the equipment is not possible. This function monitories
constantly the output level of the equipment, varying the GIG attenuator value in order to get the output level constant,
although the input level varies.
2.4.- 4th Step: Menu Back-up
In this menu, it is possible to restore configurations as well as making backups.
In case of using usually a fixed channel configuration and inputs, in order to
get a master installation, it is possible to storage the configuration into the
programmer (it allows up to 9 configurations for each model). In this manner,
what you need is just dumping the information from the programmer to the
equipment.
In the back-up menu, you can find the following options:
- Mode: It defines if you want to read data from programmer "Genius>Pro", or
if you want to write the configured data into the programmer "Pro>Genius".
- File: It defines the name of the configuration you want to recover or storage.
In case of the recording in the programmer (Genius>Pro), you will loose the
configuration stored with that number.
Press CANCEL to go back to previous menu.
Reserved for technical modifications and/or errors
User's Manual · Genius Lte
Autoleveling Result
X.- Autoleveling FAILED
1:0 2:0 3:0 4:0 5:0
6:0 7:0 8:X 9:X 10:0
10
-
Inputs
Prog CH
Auto
>Mode:Genius>Pro<
File: GENIUS ICT-8
-
GENIUS ICT
>Back-up<
Info
Standard
GENIUS ICT
Genius Lte
Version en_1.0
FTE maximal

Publicité

Table des Matières
loading

Table des Matières