This Lp appliance may be used with either a standard 20LB., 12 ¼" diameter: 18" high cylinder with right handed connection
threads and this is the maximum size lp tank allowed. By way of the included transition fitting, a smaller disposable lp tank is
permitted. Use only those with a CGA#600 connection and a capacity of either 14.1 oz or 16.4 oz . The cylinder must be
marked in accordance with the latest U.S. Department of Transportation specifications for LP gas cylinders or small tank.
(DOT. CFR49 or National Standards of Canada CAN/CSA-B359 Cylinders, Spheres and Tubes for the Transportation of
Dangerous Goods) a Propane Tank with an ODP) Overfill Prevention Device) must be used at all times.
IMPORTANT: Never connect the appliance to an unregulated gas supply.
The installation of this appliance must conform with local codes or in the absence of local codes, to the national fuel gas code,
ANSI Z223.1a-1998. Installation in Canada must be in accordance with the standard CAN/CGA- B149.2, Propane Installation
Code.
A licensed contractor or local gas company representative must perform all gas connections.
Ensure that the service supplying the appliance is fitted with a shut off valve conveniently positioned near the appliance
and giving ease of access.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 0.5 psi (3.5 kPa).
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system.
Blaze Outdoor Products Instructional Book
Page | 15