P-3600 AR G OWNER'S MANUAL
exceeded. If this condition occurs, the unit will enter thermal shutdown to ensure safety. The Extreme Temperature indicator (located
within the meter lens assembly centered directly above the blue current meters LEDs) will illuminate when maximum temperature is
present and power to all outlets of the P-3600AR G has ceased. Note that the P-3600 AR G has an internally installed fan to provide
cooling in extreme temperatures.
TROUBLESHOOTING
1.) Symptom: No power to the AC outlets; "Protection OK" indicator is not lit.
Possible Cause: Either the AC outlet to which your P-3600 AR G is connected has no AC voltage present, or there has been damage to
the unit's circuitry.
Action Needed: Plug the P-3600 AR into an AC source where a nominal 120 VAC is present. If the problem persists, the internal cir-
cuitry may be damaged and the unit will require factory service (see "Service" section below).
2.) Symptom: Extreme Voltage indicator lit.
Possible Cause: Input voltage is above 140 volts or 275 volts causing power to the unit's outlets to be shut down.
Action Needed: Correct the line voltage, and then turn the P-3600 AR G off and on with the main power switch.
3) Symptom: Temperature Range indicator is lit amber.
Possible Cause: Internal temperature of the P-3600 AR G's autoformer is approaching its temperature limit.
Action Needed: Operator should check that there is sufficient air space around P-3600 AR G, the ventilation fan is running, both air
vents are unobstructed, the load is not excessive, and that the ambient air temperature is not hot.
WARNING: If the temperature of the P-3600 AR G continues to rise, the P-3600 AR G may shutdown to prevent damage to itself. If the
P-3600 AR G goes into thermal shutdown, it may take significant time for the unit to cool down and re-power up.
4) Symptom: Extreme Temperature indicator lit.
Possible Cause: Internal temperature of the P-3600 AR G's autoformer has exceeded safe operation levels and the unit has entered
thermal shutdown.
Action Needed: Operator should check that there is sufficient air space around P-3600 AR G, the ventilation fan is running, both air
vents are unobstructed, the load is not excessive, and that the ambient air temperature is not hot. Ventilation fan will continue to run
and circulate air even while unit is shutdown in this state. Unit will re-power up once the internal temperature of the autoformer has
cooled.
NOTE: Due to the large thermal mass of the P-3600 AR G autoformer, once the autoformer reaches its high temperature limit, it will
take significant time for the transformer to cool down.
SERVICE
Questions or issues with your Furman unit should be directed to the Furman Customer Service Department, available 8AM-4PM Pacific
Time at (877) 486-4738 or via email at techsupport@furmansound.com. If a unit requires service, it must have an RA number assigned
from Furman's Customer Service Department.
Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment, and
that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please enclose a
brief note giving your name, address, phone number and a description of the problem. Please display your RA number prominently on
the front of all packages.
5 YEAR LIMITED WARRANTY
SAVE YOUR SALES RECEIPT! The receipt is your proof of purchase and confirms the product was purchased at an authorized Furman
dealer. It will need to be submitted to Furman in order to process any warranty claims.
Furman, a brand of Panamax LLC., warrants its P-3600 AR G (the "Product") as follows:
Furman warrants to the original purchaser of the product that the product sold hereunder will be free from defects in material and
workmanship for a period of five years from the date of purchase. If the product does not conform to this Limited Warranty during the
warranty period (as herein above specified), purchaser shall notify Furman of the claimed defects by calling 877-486-4738 or via email
(techsupport@furmansound.com). If the defects are of such type and nature as to be covered by this warranty, Furman shall authorize
purchaser to return the product to Furman headquarters. Warranty claims MUST be accompanied by a copy of the original purchase
invoice or receipt showing the purchase date. Shipping charges to Furman headquarters must be prepaid by the purchaser of the
product. Furman shall, at its own expense, furnish a replacement product or, at Furman's option, repair the defective product. Return
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Prestige p-3600 ar g

Table des Matières