Relay
3
Fuse holder
L1 and N already connected
to the E-Socket plug
5
6
PE
All manuals and user guides at all-guides.com
Quick start guide
2
4
PE
5
Connect wires 1, 2, 3 and 4 to the Fuse holder
5
and Relay in the junction box according to the
wiring diagram (Page 23).
The wires are number coded.
•
Connect wire 1 to the Fuse holder.
•
Connect wire 2 to position 4 on the Relay.
•
Connect wire 3 to position A1 on the Relay.
•
Connect wire 4 to position A2 on the Relay.
6
Feed wires 5, 6 and PE (yellow, green) through
the E-Socket opening at the front of the junction
box.
Take care not to damage the cables; keep them
clear of the locking mechanism so they do not
obstruct it.
6
7
Connect wires 5, 6 and PE to the E-Socket plug
according to the wiring diagram (Page 23):
•
Connect wire PE to PE.
•
Connect wire (the flat cable lugs) 5 to S1and 6 to
S2.
8
Make sure the E-Socket plug is positioned in the
upright position.Use the anti-theft screws to
mount the E-Socket plug on the junction box.
Ensure the E-Socket plug anti-theft screws are
fixed firmly. Only then will the IP54 sealing be
effective.
7
9
Place the lid on the junction box and tighten the
screws.
6
Proceed with the instruction on how to install
the E-Socket on the Eve Single Pro-line FR or
5
Double Pro-line FR to finish the installation.
8
7
E-Socket
9