Page 17
4B-4) Call mode
SIMPLEBUS - STANDARD call mode (default)
In this operating mode, the door-entry phone user is identified by a Code
field no longer than 3 digits (between 1 and 240).
The call is made as follows:
1. On the keypad, enter the code 1
2. press the key (
)
»
transmit the call to the user identified with the code 1.
SIMPLEBUS - INDIRECT CODE call mode
In this operating mode, the door-entry phone user is identified by an Indirect
Code field no longer than 6 digits and a Code field no longer than 3 digits
(between 1 and 240).
EXAMPLE: User identified by Code = 1 and Indirect Code = 1000
The call is made as follows:
1. On the keypad, enter the code 1000
2. press the key (
)
»
transmit the call to the user identified with the code 1.
SIMPLEBUS TOP call mode
In this operating mode, the door-entry phone user is identified by a 2-part
Code field; a zone field with up to 3 digits between 1 and 500) and a user
field which must have 3 digits (between 1 and 240).
The call is made as follows:
1. On the keypad, enter the code 25 015
2. press the key (
)
»
transmit the call to the user identified with the code 25 015.
SIMPLEBUS TOP – INDIRECT CODE call mode
In this operating mode, the door-entry phone user is identified by an Indirect
Code field no longer than 6 digits and a 2-part Code field; a zone field with
up to 3 digits between 1 and 500) and a user field which must have 3 digits
(between 1 and 240).
EXAMPLE: User identified by Code = 25 015 and Indirect Code = 1000
The call is made as follows:
1. On the keypad, enter the code 1000
2. press the key (
)
»
transmit the call to the user identified with the code 25 015.
The list with the listed fields can only entered by means of software
Art. 1249B set to INDIRECT CODE mode without Name field.
INITIAL CONDITION
Access carried out
at the configuration
SETTINGS
stage (see point 4A)
OPERATION
DISPLAY
Select the SETTINGS
/ SYST. PAR. / CALL
CALL MODE (0-3)*
MODE menu
using the key
The module is in
MAIN
programming mode.
The menus are
scrolled through
automatically every
2 seconds.
DESCRIPTION
N.B. The values
in brackets are
the min. and max.
VALUE:_
parameter limits
(ref. table page 6).