INSTALLATION
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR
FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local
codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts
inside.
SLIPFITTER MOUNTING
1. The slip fitter mounting fits a 2 3/8" O.D. Tenon. Place
the slip fitter over the Tenon and secure the fixture with
the 4 Set Screws on the side of the slip fitter.
2. Loosen the Locking Bolt and swivel fixture to desired
angle.
3. Tighten the Locking Bolt
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct.
Refer to wiring directions.
2. Is the fixture grounded properly?
3. Is the photocell, if used, functioning properly?
© 2016 Philips Lighting Holding B.V. All rights reserved.
www.philips.com/luminaires
Part Number 443561205860 Rev. D
Page 1 of 2
LPF3
TRUNNION MOUNTING
CAUTION: UL and C-UL listed or CSA certified liquid
tight cord grip suitable for use with three conductor type
STW flexible cord shall be used for connection to a wet
location outlet box provided by others.
To adjust the angle of the fixture using the trunnion:
1. Loosen the Pivot Bolts & angle locking screw.
2. Adjust fixture to desired angle.
3. Tighten Pivot Bolts & angle locking screw.
WIRING
Universal voltage drivers permits operation at 120V to
277VAC, 50/60 Hz or 347V 60Hz.
1. Connect the BLACK fixture lead to the (+) LINE supply
lead.
2. Connect the WHITE fixture lead to the (-) COMMON
supply lead.