Technical Specifications - Polar Refrigeration GL193 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Telephone Helpline: 0845 146 2887 (United Kingdom)
Troubleshooting
Fault
The appliance is
not working
Appliance is noisy
or works
intermittently
Compressor runs
but no ice is made
Ice cubes not fully
formed
Not producing
enough ice
Water comes
through curtain

Technical Specifications

Model
Voltage
GL193 230V 50Hz
Probable Cause
The appliance is not switched
on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Ambient temperature below
10°C
Water supply
Power fluctuations
Refrigerant leak or block in the
refrigerant system
Bin is full
Blocked nozzle
First ice making cycle
Ice melted
Spray bar dislodged/misaligned Reattach spray bar
Condensor Blocked
Ambient temperature too high
Water pressure too low
Condensor Blocked
Spray bar dislodged/misaligned Reattach spray bar
Ambient
Power Current
Range
260W
1.8A
16C-32C
Check the appliance is plugged in correctly and
switched on
Call POLAR agent or qualified technician
Replace the plug fuse
Check power supply
Call POLAR agent or qualified technician
Move appliance to a warmer position
Check water supply is on and supply hoses are
not blocked
Turn off the ice maker and restart after 3 minutes
Call POLAR agent or qualified technician
Empty bin
Clean nozzle jets
Use ice from second cycle
Do not leave ice in bin for extended periods
Clean Condensor
Relocate appliance to a suitable position
Check water inlet hose/inlet hose filter for
blockages
Clean Condensor
Ice
Making
Refrigerant
Capacity
22kg/
R290a
24hour
43.5g
Action
Dimensions
Weight
h x w x d mm
637 x 380 x 520
UK
(kg)
33
4

Publicité

Table des Matières
loading

Table des Matières