Fix Air Lock To Mounting Plate - Lenze E93ZWL Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Show/Hide Bookmarks
3.4.2
l
Installation of the E93ZWL air lock

Fix air lock to mounting plate

Note!
The mounting plate must be suspended in the control cabinet.
Lenze recommends to install a gasket between the air lock and the top of the
control cabinet. The gasket (yard ware) is not part of the items supplied with the
air locks.
0
1 1
1
2
Fixing collar of air lock
Gasket
Top of control cabinet
Hexagon socket screw M8 × 25 mm
Spring washer M8
1. Glue the gasket under the fixing collar of the air lock and insert the air lock into the recess in
the top of the control cabinet.
2. Fix the air lock to the mounting plate exactly at the illustrated points using 2 hexagon socket
screws and spring washers.
Preparations at the top of the control cabinet
2
3
4
E93ZWLX DE/EN/FR 1.0
93ZWL017