Resetting The Thermostat (Default Settings); Power Outage - Honeywell Home RLV4305A1014 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LO is displayed
HI is displayed
E1, E2 is displayed

Resetting the thermostat (default settings)

NOTE: All parameters, except the clock (time and day), return to their default
settings when the thermostat is reset.
1. Press the Mode button until Standby appears on the screen.
2. Press the
button for 6 seconds.
3. The thermostat will display rSt (reset) for 2 seconds to indicate it is reset
and will then return to normal display.

Power outage

During a power outage, LP (low power) appears for the first minute. Then the
screen becomes blank. The settings are stored in memory. After the initial
installation, product must be connected to power for a minimum of two hours
to enable the power outage feature. However, if the power failure exceeds 4
hours, the thermostat's clock must be readjusted and, if you are using the
automatic Daylight Saving Time changeover function, it must be re-enabled.
When power returns, the thermostat will return to the mode of operation
active prior to the power failure.
Specifications
Supply: 120/240 VAC, 60 Hz
Minimum load: 0.83 A (resistive only)
Maximum load: 14.6 A (resistive only)
Display range: 32 °F to 99 °F (0 °C to 50.0 °C)
Setpoint range: 41 °F to 86 °F (5.0 °C to 30.0 °C)
Resolution: 1 °F (0.5 °C)
Storage temperature: -4 °F to 120 °F (-20 °C to 50 °C)
The measured temperature is below the display range. Heating is
activated.
The measured temperature is above the display range.
The thermostat performance is reduced due to a sensor error. Please
contact technical support for more information.
200 W @ 240 V AC
100 W @ 120 V AC
3500 W @ 240 V AC
1750 W @ 120 V AC