Application
This thermostat can be used to control an electric heating system such as a
baseboard heater or a convector.
The thermostat CANNOT be used with:
a resistive load under 0.83 A
a resistive load over 8.3 A
a system driven by a contactor or a relay (inductive load)
a fan-forced heating system (e.g. : fan-forced convector)
a central heating system.
WARNING Electrical Shock Hazard.
This thermostat is a line voltage control (120–240 Volts). Do not install it if you
are not completely familiar with house wiring. If handled improperly, there is risk
of electric shock hazard, which may cause serious injury or death.
RLV3120
Do you need assistance? We are here to help.
Call 1-800-468-1502 for wiring assistance before returning the
thermostat to the store.
C
M37957A

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell Home RLV3120

  • Page 1 RLV3120 Non-programmable Thermostat Owner’s Manual Read and save these instructions. For help please visit resideo.com M37957A Application This thermostat can be used to control an electric heating system such as a baseboard heater or a convector. The thermostat CANNOT be used with: a resistive load under 0.83 A...
  • Page 2: Temperature Display And Setting

    ATTENTION: MERCURY RECYCLING NOTICE This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash. For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at...
  • Page 3: Removing The Faceplate

    Removing the faceplate WARNING TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRIC SHOCK. Loosen the screw holding the faceplate to the base. The screw cannot be completely removed and remains captive on the base. Remove the faceplate from the base M38973 by pulling the bottom half.
  • Page 4: Installing The Faceplate

    Installing the faceplate Install the base onto an electrical box. Reinstall the faceplate on the base and secure it in place with the screw. M38974 NOTE: Keep the air vents of thermostat clean and unobstructed at all times. Selecting the temperature display format To select the temperature display format: 1.
  • Page 5 Specifications Supply: 120/240 VAC, 60 Hz Minimum load: 0.83 A (resistive only) 200 W @ 240 V AC 100 W @ 120 V AC Maximum load: 8.3 A (resistive only) 2000 W @ 240 VAC 1000 W @ 120 VAC Display range: 0 °C to 50 °C (32 °F to 99 °F) Setpoint range: 5 °C to 30 °C (40 °F to 85 °F) Storage: -20 °C to 50 °C (-4 °F to 120 °F)
  • Page 6 33-00149EF—09 M.S. Rev. 05-22 | Printed in United States © 2022 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.
  • Page 7 RLV3120 Thermostat non programmable Manuel du propriétaire Veuillez lire le mode d’emploi et le conserver en lieu sûr. Pour obtenir de l’aide veuillez visiter resideo.com M37957A Application Ce thermostat a été conçu pour commander un appareil de chauffage électrique tel qu’une plinthe chauffante ou un convecteur.
  • Page 8: Affichage Et Réglage De La Température

    ATTENTION: AVIS RELATIF AU RECYCLAGE DU MERCURE Ce produit ne contient aucun mercure. Cependant, ce produit peut remplacer un produit qui contient du mercure. Le mercure et les produits contenant du mercure ne doivent pas être jetés aux ordures ménagères. Pour obtenir plus d›informations pour savoir comment et où...
  • Page 9: Enlever La Façade

    Enlever la façade AVERTISSEMENT METTRE LE SYSTÈME DE CHAUFFAGE HORS TENSION AFIN D’ÉVITER TOUT RISQUE DE CHOC ÉLECTRIQUE. Desserrer la vis qui retient la façade du thermostat à la base. La vis ne peut être complètement enlevée et reste captive sur la base. Séparer M38973 la façade de la base en tirant sur la partie inférieure du thermostat.
  • Page 10: Installer La Façade

    Installer la façade Installer la base sur une boîte électrique. Remettre la façade du thermostat sur la base et resserrer la vis. M38974 REMARQUE : Garder les ouvertures d’aération du thermostat propres et dégagées en tout temps. Selectionner le format d’affichage de la température Pour selectionner le format d’affichage de la température : 1.
  • Page 11: Caractéristiques

    Caractéristiques Alimentation : 120/240 V c.a., 60 Hz Charge minimale : 0,83 A (résistive seulement) 200 W @ 240 V c.a. 100 W @ 120 V c.a. Charge maximale : 10,4 A (résistive seulement) 2000 W @ 240 V c.a. 1000 W @ 120 V c.a.
  • Page 12: Garantie Limitée D'un An

    33-00149EF—09 M.S. Rev. 05-22 | Imprimé aux États-Unis © 2022 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc.