DIAGNOSTIC SYSTEM
• TROUBLESHOOTING MESSAGES
- « CLOS Lid » message
ª
The appliance is powered up but the lid has been left
open. Close the lid.
- « OPEn And CLOS Lid » message
ª
ª
The appliance is powered up and the lid is closed.
Open the lid and close it again.
- « PrES StOP » message
ª
The screen will display this message in the following
two cases:
- An attempt has been made to start the machine
before Stage 3 is completed (see page 8). Wait for
the screen to display "0.00", then press the "off"
button.
- The appliance is powered up but unused, or has
been running for more than two hours without the
"off" button being pressed. Wait for the screen to
display "0.00", then press the "off" button.
- « iSbC » message
This message indicates that the two lid arm safety
switches ("iSbC") are not being detected.
18
Checks to be made in the following order:
1) Check that the lid has been closed properly.
2) Check that the two safety switches both move free-
ly when the lid is opened and closed.
3) Check (with an ohmmeter) that the contacts of
these two safety switches are both closed. Check
the relevant wiring.
ª
If the two switches are properly closed and this
message remains on the screen, either get the
control board checked over or have it replaced.
- « iSCO » message
The lid's magnetic safety switch ("iSCO") is not being
detected.
Checks to be carried out in the following order:
1) Check that the lid and, more specifically, its
magnet, are correctly positioned.
2) Check (with an ohmmeter) that the safety switch's
contact is closed. Check the relevant wiring. If
necessary, remove the lid and place a sufficiently
powerful magnet next to the magnetic switch.
If the switch is properly closed but this message
remains on the screen, either get the control board
checked over or have it replaced.
- « iSbA » « or » « iSCU » « thEn »
« iSbC » « And » « iSCO » message
ª
ª
ª
Either the tilt safety switch ("iSbA") or the magnetic
bowl safety switch ("isCU) is not being detected.
Checks to be made in the following order:
1) Check that the bowl has resumed its vertical
position
2) Check that the bowl is properly locked at the right
angle
3) Check (with an ohmmeter) that the contact of the
tilt switch is closed and check the relevant wiring.
4) Check (with an ohmmeter) that the bowl presence
switch's contact is closed. If necessary, remove the
bowl
and
place
a
sufficiently
magnet close to the magnetic switch. Check the
relevant wiring
5) If the tilt and bowl switches are both closed, carry
out the checks described above for the "iSbC"
and "iSCO" messages.
If all four tilt, bowl, lid arm and lid switches are
closed but this message remains on the screen,
either get the control board checked over or have it
replaced.