FAILURE
ERROR
LIKELY FAILURE CONDITION
F1
E0
Oven user interface failure
Internal
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait 10
seconds, and power on).
PROCEDURE: Before proceeding, verify the error code by entering the
Diagnostics mode and selecting "Error Diagnostics."
NOTE: If other error codes are stored, troubleshoot those other error codes
first.
1.
Unplug oven or disconnect power.
2.
Confirm the control panel assembly is grounded to the oven chassis. If it
is, go to Step 6. If it is not, fix the connection.
3.
Reassemble all parts and panels before operating.
4.
Plug in oven or reconnect power and cycle power.
5.
If error persists unplug oven or disconnect power.
6.
Replace HMI-Central/UI board.
7.
Reassemble all parts and panels before operating.
8.
Plug in oven or reconnect power and cycle power.
9.
If error persists after HMI-Central/UI board is replaced, unplug oven or
disconnect power and replace Control Panel Assembly.
10. Reassemble all parts and panels before operating.
11. Plug in oven or reconnect power. Follow the on-screen prompts for model
selection.
12. Verify operation is normal. Enter Diagnostics mode, select "Error
Diagnostics," and clear the history. If the Control Panel Assembly was
replaced, there is no need to clear the error history.
FAILURE
ERROR
F1
E1
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait 10
seconds, and power on).
PROCEDURE: Before proceeding, verify the error code by entering the
Diagnostics mode and selecting "Error Diagnostics."
NOTE: If other error codes are stored, troubleshoot those other error codes
first.
1.
Unplug oven or disconnect power.
2.
Replace the Copernicus Appliance Manager.
3.
Reassemble all parts and panels before operating.
4.
Plug in oven or reconnect power.
5.
If error persists after Copernicus Appliance Manager is replaced, unplug
oven or disconnect power, and then go to Step 6. If not, go to Step 9.
6.
Replace Control Panel Assembly.
7.
Reassemble parts and panels before operating.
8.
Plug in oven or reconnect power.
9.
Follow the on-screen prompts to select the model number
10. Verify operation is normal. Enter Diagnostics mode, select "Error
Diagnostics," and clear the history. If the Control Panel Assembly was
replaced, there is no need to clear the error history.
9
LIKELY FAILURE CONDITION
Internal oven ACU error