Jenn-Air JMW2427IL Mode D'emploi page 19

Masquer les pouces Voir aussi pour JMW2427IL:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FAILURE
ERROR
LIKELY FAILURE CONDITION
F6
E1
Over temperature
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait 10
seconds, and power on).
PROCEDURE: Before proceeding, verify the error code by entering the
Diagnostics mode and selecting "Error Diagnostics."
1.
Unplug oven or disconnect power.
2.
Check for elements shorted to ground. Check resistance of elements:
a. PX4-2 and PX3-2 to check Broil element (13.2 Ω to 14.6 Ω)
b. PX1-1 and PX3-2 to check Bake element (19 Ω to 21 Ω)
c. PX1-3 and PX3-2 to check Upper Convect element (15.2 Ω to 17.3 Ω)
3.
If any element is shorted to ground, replace the element.
4.
Check for shorted relays.
For Core Models: Disconnect PX1 and PX4 connectors
and check for shorts between:
a. PX1-1 and PX1-2 (Bake relay)
b. PX1-3 and PX1-4 (Up Convect relay)
c. PX4-1 and PX4-2 (Broil relay)
Copernicus Appliance Manager
K11
PX4
K10
K2
PX1
K3
PX3
5.
If there is a shorted relay, replace the Copernicus Appliance Manager
control. Go to Step 9.
6.
If everything is correct, disconnect connector P3 from the Copernicus
Appliance Manager.
7.
Measure the resistance of the oven sensor. It should be 1000 Ω to 1200 Ω
at 77°F (25°C).
N L2 L1
BU
Broil - 4000W
1
BU
BU
2
Bake - 2800W
RD
RD
1
BK
2
3
YL
YL
4
Convect - 3200W
BK
RD
RD
1
2
Temperature Limiter
Oven Temp 338°F (170°C)
RD/WH
8.
Check sensor for short to ground. If checks on sensor are not correct,
replace the sensor and repeat the checks.
Oven
Temperature
Sensor
9.
Reassemble all parts and panels before operating.
10. Plug in oven or reconnect power.
11. Enter the Diagnostics menu and select "Sensors & Switches" to verify
that the corresponding oven temperature displayed is correct (ambient
temperature). If not, unplug oven or disconnect power, and replace the
Copernicus Appliance Manager board.
NOTE: On the status screen, the unit of measurement is Celsius.
12. Reassemble all parts and panels before operating.
13. Plug in oven or reconnect power.
14. Verify operation is normal. Enter Diagnostics mode, select "Error
Diagnostics," and clear the history.
19
V
1
V
2
3
Copernicus
4
5
Appliance Manager
6
7
8
9
10
P3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jmw2430imJmw2430il

Table des Matières