FOR SERVICE TECHNICIAN'S USE ONLY
FAILURE
ERROR
LIKELY FAILURE CONDITION
F4
E1
Microwave cavity temperature sensor error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait 10
seconds, and power on). After powering on, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function that uses the temperature sensor, such as
a Convect cycle. Wait 1 minute, and then verify that the failure happens again.
1.
Unplug oven or disconnect power.
2.
Check that the P22 connection of the Microwave Appliance Manager is
firmly connected. If it is, go to Step 3. If it is not, reconnect and go to
Step 5.
Cavity
Thermistor
3.
Disconnect connector P22 from the Microwave Appliance Manager, and
measure the resistance of the thermistor. It should be (approximately)
230 kΩ at 77°F ± 10°F (25°C ± 10°C).
4.
Check thermistor for short to ground. If check on thermistor is not
correct, replace the thermistor. If thermistor check is correct, replace the
Microwave Appliance Manager.
5.
Reassemble all parts and panels before operating.
6.
Plug in oven or reconnect power.
7.
Verify operation is normal. Enter the Diagnostics menu, select "Error
Diagnostics," and clear the history.
Microwave
Appliance
Manager
P22
FAILURE
ERROR
LIKELY FAILURE CONDITION
F4
E2
Magnetron temperature sensor error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait 10
seconds, and power on). After powering on, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function. Wait 1 minute, and then verify that the
failure happens again.
1.
Unplug oven or disconnect power.
2.
Check that the P21 connection of the Microwave Appliance Manager is
firmly connected. If it is, go to Step 3. If it is not, reconnect and go to
Step 5.
Magnetron
Thermistor
3.
Disconnect connector P21 from the Microwave Appliance Manager, and
measure the resistance of the thermistor. It should be (approximately)
10 kΩ at 77°F ± 10°F (25°C ± 10°C).
4.
Check thermistor for short to ground. If check on thermistor is not
correct, replace the thermistor. If thermistor check is correct, replace the
Microwave Appliance Manager.
5.
Reassemble all parts and panels before operating.
6.
Plug in oven or reconnect power.
7.
Verify operation is normal. Enter the Diagnostics menu, select "Error
Diagnostics," and clear the history.