TULS/TULM/TULL
NOTE:
Install luminaire as per traffic direction label
MOUNTING HOLES PATTERNS FOR FIXED BRACKET
B
+15°
+10°
+5°

ELECTRICAL CONNECTIONS

1. Open fixture access door.
2. Connect the black fixture lead to the input voltage
supply or Hot 1 (208V/240V/480V wiring).
3. Connect the white fixture lead to the neutral
supply or Hot 2 (208V/240V/480V wiring).
4. Connect the Green ground lead to the incoming
ground wire.
5. If Dimming is an option, connect the purple
dimming positive lead to the supply dimming
positive lead and the grey dimming negative lead
to the supply dimming negative lead.
6. Close fixture access door and tighten the door
screw to 27 in-lbs torque or properly close latches
if latch option was selected.
3 poles
Terminal Block
2-14 AWG
20 to 25 lbs.in
page
Page 2

Installation Instructions

Screws
Latches
Hole for connectors
Fix Brk
B
TULS
16.50
TULM
16.50
TULL
24.50
-5°
-10°
-15°
CAUTION Prevent
over torque
damage
Do not over torque
nuts and bolts

Mounting Brackets

1. Secure to surface with (4) 3/8 -16'' studs or bolts (by others).
See mounting hole patterns.
2. Unscrew screws (2) on door or open latches (2) to gain to
terminal block and electrical components.
3. Install connector/sealing washer/lock nut/power cord (by
others). Hole for a connector ½". Torque as recommended by
supplier.
4. Connect the service leads to the terminal block. Tighten the
set screws between 20 and 25 lbs.in..
5. To adjust the angle, loosen the (2) ½-13'' bolts located in the
Swivel (do not remove bolts). Loosen only enough to allow
rotation.
6. For luminaires with NEMA receptacle, the aiming angle must
be restricted to 0° to 90° from horizontal aim.
7. Rotate the luminaire to the desired position and retighten the
bolts loosened in step 5 to approx. 45 ft.-lbs.
8. Upon final installation, the installer must inspect the bracket
to ensure adequate clearance.
MOUNTING HOLES PATTERNS FOR SWIVEL BRACKET
90°
Suggested electrical connection with
Liquid Tight Cordgrip IP66 rated.
Suggested electrical connection with
Liquid Tight Cord grip IP66 rated. Liquid
tight IP66 rated connector must be used
and properly installed. Non-water tight
installation will void warranty.
Adjustment Bolts
442295373671-R1
B
Swivel
TULS
TULM
TULL
NOTE: Luminaire with NEMA
Twist Lock Receptacle option
aiming is restricted to 0°-90°
75 ft.-lbs
per ANSI C136.10