TULS/TULM/TULL
MOUNTING HOLES PATTERNS
VLM Montage STD
DETAIL 1
SV
BRACKETS
Safety chain attachment
point (if required).
page 4
Installation Instructions
SV BRACKETS
DETAIL 2
Instructions for Attaching Luminaire to VLM Bracket
1. Secure the attachment VLM bracket to preferred mounting (VLM
STD, MTQ).
2. Attach luminaire to VLM bracket and secure with (4) 3/8 -16'' in
threaded nuts. See mounting hole (A) patterns for location with
SV BRACKET. See mounting hole (B) patterns for location with
FIXED BRACKETS.
3. Make sure to install the (4) 3/8 '' lock washers and (4) 3/8 '' flat
washers. See detail 1.
4. All bolts should be securely tightened to 20 ft.-lbs.
5. To adjust luminaire angle, see SV Bracket installation instructions.
Hole diameter for other mounting with VLM bracket
FIXED
VLM STD (WW0/WW2/WW3)
BRACKETS
VLM STD (STD pattern)
MTQ
NOTE: Angle adjustment can be made before luminaire
installation.
442295373671-R1
FIXED BRACKETS
DETAIL 1
DETAIL 2
1/2''
7/16''