• the minimum required number of bends.
• the minimum required length to avoid vibrations and reduce the suction per-
formance of the hood.
You are required to insulate the pipes if it passes through cold environments.
In the presence of motors with 500 CFM or higher, a check valve is present to
prevent external air flowing back.
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, air passes through the active carbon filters HP
(optional) to be purified and is then recycled into the environ-
ment. Ensure that the active carbon filters HP are assembled
into the hood, if not, install them as indicated in the assembly
instructions.
In this version the check valve must not be assembled: remove it if it is
on the air outlet fitting of the motor.
ASSEMBLY INSTRUCTIONS
only intended for personnel qualified
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for
each case, follow the specific steps provided for the required
installation.
SRS SYSTEM SETTING
The SRS system reduces the maximum air flow rate that can be set
in the hood.
This makes the hood compliant with local building regulations.
MAX SPEED LEVEL 3
1
Apply the label
Code
Serial n.
Fig. 1: Set maximum speed 3:
Press keys
+
for 5 seconds
All keys flash.
Within 5 seconds, press and hold the
If all the keys light up and are steady, the setting procedure
has been successful.
(only for Plane NRS)
Max Speed
3
Selection
key for 5 seconds
MAX SPEED LEVEL 2
2
Apply the label
Code
Serial n.
Fig. 2: Set maximum speed 2:
Press keys
+
for 5 seconds. All keys flash.
Within 5 seconds, press and hold the
If all the keys light up and are steady, the setting procedure
has been successful.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes
and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours
and odours. By means of the Timer function, it is possible to set auto switch-off
function which will allow the hood to turn off automatically after 15 minutes of
operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity consump-
tion.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
The active carbon filters must be replaced every 3-4 months, depending on the
use of the hood.
For further details see the "MAINTENANCE" chap.
17
Max Speed
2
Selection
key for 5 seconds