Hendi 209882 Mode D'emploi page 5

Masquer les pouces Voir aussi pour 209882:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Defects
Defect
Boiler does not work at all.
Boiler switches off
automatically.
Boiler does not reach the
selected temperature.
When in doubt always contact your supplier!
De-scaling
The orange indicator light will be illuminated when
the urn gets too hot and needs to be cleaned. Hard
water will cause a build-up of calcium and limes-
cale on the heating element. To keep the urn in
optimum operating condition and ensure each use
will result in the best-tasting beverage, we recom-
mend de-scaling when you find build-up on the
heating element.
• Pour 100 ml fresh or condensed lemon juice on
the heating element.
• Wait 5~6 minutes to allow the lemon juice to loos-
en the build-up.
Technical specification
Item no.
Operating voltage and
frequency
Rated input power
Protection class
Capacity
Dimensions
Remark: Technical specification is subjected to change without prior notification.
Warranty
Any defect affecting the functionality of the ap-
pliance which becomes apparent within one year
after purchase will be repaired by free repair or re-
placement provided the appliance has been used
and maintained in accordance with the instructions
and has not been abused or misused in any way.
Your statutory rights are not affected. If the appli-
ance is claimed under warranty, state where and
Problem
Neither red light
nor indicator light is
illuminated.
The red light is not
illuminated.
Green light is not
illuminated.
209882
10L
340x227x(H)468 mm
Cause
No mains voltage.
Boiler has exceeded
maximum safety limits.
Thermostat does not work.
Heating element does not
work.
• Rub lightly and gently with a brush with soft bris-
tles.
• Repeat steps 1~3, until build-up has been re-
moved.
• Use a dry cloth to wipe the lemon juice away.
• Pour some clean water into the urn and brush
the heating element lightly and gently until there
is no more lemon taste or smell.
Now you can use the urn again.
209899
220-240V~50/60Hz
2200W
Class I
20L
387x275x(H)595 mm
when it was purchased and include proof of pur-
chase (e.g. receipt).
In line with our policy of continuous product devel-
opment we reserve the right to change the product,
packaging and documentation specifications with-
out notice.
Possible solution
Check the electrical
connections.
Once it has cooled off, the
boiler will switch on again
automatically.
Contact your supplier.
209929
20L
387x275x(H)595 mm
5
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

209899209929