Extension Cords; Voltage And Circuit Protection - Porter Cable CPFAC2600P Manuel

Masquer les pouces Voir aussi pour CPFAC2600P:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com

Extension Cords

Using extension cords is not recommended. The use of extension cords will
cause voltage to drop resulting in power loss to the motor and overheating.
Attach extra air hoses at the air outlet instead of using extension cords.
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot
receptacle that will accept the plug on the product
in good condition
no longer than 50 feet
12 gauge (AWG) or larger. (Wire size increases as gauge number
decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR
16 AWG.)

Voltage and Circuit Protection

Refer to the Specification Chart for the voltage and minimum branch circuit
requirements.
Certain air compressors can be operated on a 15 amp circuit if the following
conditions are met.
1.
Voltage supply through branch circuit is 15 amps.
2.
Circuit is not used to supply any other electrical needs (lights, appliances,
etc.).
3.
Extension cords comply with specifications.
4.
Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay
fuse. NOTE: If compressor is connected to a circuit protected by fuses,
use only time delay fuses. Time delay fuses should be marked "D" in
Canada and "T" in the US.
If any of the above conditions cannot be met, or if operation of the compressor
repeatedly causes interruption of the power, it may be necessary to operate it
from a 20 amp circuit. It is not necessary to change the cord set.
D27856
10 - ENG

Publicité

Table des Matières
loading

Table des Matières